Anatomically Informed GREIT Reconstruction: Improving EIT Imaging for Lung Monitoring

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ludwig, Maximilian, Eichinger, Carolin M., Sablewski, Armin, Frerichs, Inéz, Becher, Tobias, Wall, Wolfgang A.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911463535280128
author Ludwig, Maximilian
Eichinger, Carolin M.
Sablewski, Armin
Frerichs, Inéz
Becher, Tobias
Wall, Wolfgang A.
author_facet Ludwig, Maximilian
Eichinger, Carolin M.
Sablewski, Armin
Frerichs, Inéz
Becher, Tobias
Wall, Wolfgang A.
contents Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient's thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. Anatomical features from CT data were included by customizing background conductivity and GREIT training target distribution. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Integrating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients.
format Preprint
id arxiv_https___arxiv_org_abs_2508_00640
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Anatomically Informed GREIT Reconstruction: Improving EIT Imaging for Lung Monitoring
Ludwig, Maximilian
Eichinger, Carolin M.
Sablewski, Armin
Frerichs, Inéz
Becher, Tobias
Wall, Wolfgang A.
Medical Physics
Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient's thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. Anatomical features from CT data were included by customizing background conductivity and GREIT training target distribution. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Integrating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients.
title Anatomically Informed GREIT Reconstruction: Improving EIT Imaging for Lung Monitoring
topic Medical Physics
url https://arxiv.org/abs/2508.00640