Diagnostic Accuracy of Open-Source Vision-Language Models on Diverse Medical Imaging Tasks
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2025
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866913971486851072 |
|---|---|
| author | Müller-Franzes, Gustav Jutz, Debora Kather, Jakob Nikolas Kuhl, Christiane Nebelung, Sven Truhn, Daniel |
| author_facet | Müller-Franzes, Gustav Jutz, Debora Kather, Jakob Nikolas Kuhl, Christiane Nebelung, Sven Truhn, Daniel |
| contents | This retrospective study evaluated five VLMs (Qwen2.5, Phi-4, Gemma3, Llama3.2, and Mistral3.1) using the MedFMC dataset. This dataset includes 22,349 images from 7,461 patients encompassing chest radiography (19 disease multi-label classifications), colon pathology (tumor detection), endoscopy (colorectal lesion identification), neonatal jaundice assessment (skin color-based treatment necessity), and retinal fundoscopy (5-point diabetic retinopathy grading). Diagnostic accuracy was compared in three experimental settings: visual input only, multimodal input, and chain-of-thought reasoning. Model accuracy was assessed against ground truth labels, with statistical comparisons using bootstrapped confidence intervals (p<.05). Qwen2.5 achieved the highest accuracy for chest radiographs (90.4%) and endoscopy images (84.2%), significantly outperforming the other models (p<.001). In colon pathology, Qwen2.5 (69.0%) and Phi-4 (69.6%) performed comparably (p=.41), both significantly exceeding other VLMs (p<.001). Similarly, for neonatal jaundice assessment, Qwen2.5 (58.3%) and Phi-4 (58.1%) showed comparable leading accuracies (p=.93) significantly exceeding their counterparts (p<.001). All models struggled with retinal fundoscopy; Qwen2.5 and Gemma3 achieved the highest, albeit modest, accuracies at 18.6% (comparable, p=.99), significantly better than other tested models (p<.001). Unexpectedly, multimodal input reduced accuracy for some models and modalities, and chain-of-thought reasoning prompts also failed to improve accuracy. The open-source VLMs demonstrated promising diagnostic capabilities, particularly in chest radiograph interpretation. However, performance in complex domains such as retinal fundoscopy was limited, underscoring the need for further development and domain-specific adaptation before widespread clinical application. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2508_01016 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Diagnostic Accuracy of Open-Source Vision-Language Models on Diverse Medical Imaging Tasks Müller-Franzes, Gustav Jutz, Debora Kather, Jakob Nikolas Kuhl, Christiane Nebelung, Sven Truhn, Daniel Image and Video Processing Computer Vision and Pattern Recognition This retrospective study evaluated five VLMs (Qwen2.5, Phi-4, Gemma3, Llama3.2, and Mistral3.1) using the MedFMC dataset. This dataset includes 22,349 images from 7,461 patients encompassing chest radiography (19 disease multi-label classifications), colon pathology (tumor detection), endoscopy (colorectal lesion identification), neonatal jaundice assessment (skin color-based treatment necessity), and retinal fundoscopy (5-point diabetic retinopathy grading). Diagnostic accuracy was compared in three experimental settings: visual input only, multimodal input, and chain-of-thought reasoning. Model accuracy was assessed against ground truth labels, with statistical comparisons using bootstrapped confidence intervals (p<.05). Qwen2.5 achieved the highest accuracy for chest radiographs (90.4%) and endoscopy images (84.2%), significantly outperforming the other models (p<.001). In colon pathology, Qwen2.5 (69.0%) and Phi-4 (69.6%) performed comparably (p=.41), both significantly exceeding other VLMs (p<.001). Similarly, for neonatal jaundice assessment, Qwen2.5 (58.3%) and Phi-4 (58.1%) showed comparable leading accuracies (p=.93) significantly exceeding their counterparts (p<.001). All models struggled with retinal fundoscopy; Qwen2.5 and Gemma3 achieved the highest, albeit modest, accuracies at 18.6% (comparable, p=.99), significantly better than other tested models (p<.001). Unexpectedly, multimodal input reduced accuracy for some models and modalities, and chain-of-thought reasoning prompts also failed to improve accuracy. The open-source VLMs demonstrated promising diagnostic capabilities, particularly in chest radiograph interpretation. However, performance in complex domains such as retinal fundoscopy was limited, underscoring the need for further development and domain-specific adaptation before widespread clinical application. |
| title | Diagnostic Accuracy of Open-Source Vision-Language Models on Diverse Medical Imaging Tasks |
| topic | Image and Video Processing Computer Vision and Pattern Recognition |
| url | https://arxiv.org/abs/2508.01016 |