$β$-Ga$_2$O$_3$--Based Radiation Detector for Proton Therapy

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Ellis, Hunter D., Rahaman, Imteaz, Hillas, Apostoli, Li, Botong, Sarkar, Vikren, Fu, Kai
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908479447367680
author Ellis, Hunter D.
Rahaman, Imteaz
Hillas, Apostoli
Li, Botong
Sarkar, Vikren
Fu, Kai
author_facet Ellis, Hunter D.
Rahaman, Imteaz
Hillas, Apostoli
Li, Botong
Sarkar, Vikren
Fu, Kai
contents Intensity modulated proton therapy (IMPT) is an advanced cancer treatment modality that offers significant advantages over conventional X-ray therapies, particularly in its ability to minimize radiation dose beyond the tumor target. This reduction in unnecessary irradiation exposure significantly lowers the risk to surrounding healthy tissue and reduces side effects compared to conventional X-ray treatments. However, due to the high complexity of IMPT plans, each plan must be independently validated to ensure the safety and efficacy of the radiation exposure to the patient. While ion chambers are currently used for this purpose, their limitations-particularly in angled-beam measurements and multi-depth assessments-hinder their effectiveness. Silicon-based detectors, commonly used in X-ray therapy, are unsuitable for IMPT due to their rapid degradation under proton irradiation. In this study, a $β$-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector was evaluated and compared with a commercial ion chamber using a MEVION S250i proton accelerator. The $β$-Ga$_2$O$_3$ detector demonstrated reliable detection of single-pulse proton doses as low as 0.26 MU and exhibited a linear charge-to-dose relationship across a wide range of irradiation conditions. Furthermore, its measurement variability was comparable to that of the ion chamber, with improved sensitivity observed at higher bias voltages. These results highlight the strong potential of $β$-Ga$_2$O$_3$ as a radiation-hard detector material for accurate dose verification in IMPT.
format Preprint
id arxiv_https___arxiv_org_abs_2508_03605
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle $β$-Ga$_2$O$_3$--Based Radiation Detector for Proton Therapy
Ellis, Hunter D.
Rahaman, Imteaz
Hillas, Apostoli
Li, Botong
Sarkar, Vikren
Fu, Kai
Medical Physics
Materials Science
Intensity modulated proton therapy (IMPT) is an advanced cancer treatment modality that offers significant advantages over conventional X-ray therapies, particularly in its ability to minimize radiation dose beyond the tumor target. This reduction in unnecessary irradiation exposure significantly lowers the risk to surrounding healthy tissue and reduces side effects compared to conventional X-ray treatments. However, due to the high complexity of IMPT plans, each plan must be independently validated to ensure the safety and efficacy of the radiation exposure to the patient. While ion chambers are currently used for this purpose, their limitations-particularly in angled-beam measurements and multi-depth assessments-hinder their effectiveness. Silicon-based detectors, commonly used in X-ray therapy, are unsuitable for IMPT due to their rapid degradation under proton irradiation. In this study, a $β$-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector was evaluated and compared with a commercial ion chamber using a MEVION S250i proton accelerator. The $β$-Ga$_2$O$_3$ detector demonstrated reliable detection of single-pulse proton doses as low as 0.26 MU and exhibited a linear charge-to-dose relationship across a wide range of irradiation conditions. Furthermore, its measurement variability was comparable to that of the ion chamber, with improved sensitivity observed at higher bias voltages. These results highlight the strong potential of $β$-Ga$_2$O$_3$ as a radiation-hard detector material for accurate dose verification in IMPT.
title $β$-Ga$_2$O$_3$--Based Radiation Detector for Proton Therapy
topic Medical Physics
Materials Science
url https://arxiv.org/abs/2508.03605