Towards integrated sensors for optimized OCT with undetected photons
Fuente:
arXiv
Guardado en:
| Autores principales: | , , , , , |
|---|---|
| Formato: | Preprint |
| Publicado: |
2025
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1866913978952712192 |
|---|---|
| author | Roeder, Franz Pollmann, René Quiring, Viktor Eigner, Christof Brecht, Benjamin Silberhorn, Christine |
| author_facet | Roeder, Franz Pollmann, René Quiring, Viktor Eigner, Christof Brecht, Benjamin Silberhorn, Christine |
| contents | The development of practical sensors for optical coherence tomography (OCT) with undetected photons requires miniaturization via integration. To be practical, these sensors must exhibit a large spectral bandwidth and a high brightness, which are linked to a high axial resolution and a sufficient signal to noise ratio, respectively. Here, we combine these requirements in a scheme for OCT-measurements with undetected photons based on nonlinear Ti:LiNbO$_3$ waveguides. We investigate the performance benchmarks of the commonly used SU(1,1) scheme in comparison to an induced coherence scheme and find that the latter is actually better suited when implementing measurements with undetected photons in integrated systems. In both schemes, we perform pump gain optimization and OCT measurements with undetected photons with an axial resolution as low as 28 $\mathrmμ$m. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2508_05320 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Towards integrated sensors for optimized OCT with undetected photons Roeder, Franz Pollmann, René Quiring, Viktor Eigner, Christof Brecht, Benjamin Silberhorn, Christine Quantum Physics The development of practical sensors for optical coherence tomography (OCT) with undetected photons requires miniaturization via integration. To be practical, these sensors must exhibit a large spectral bandwidth and a high brightness, which are linked to a high axial resolution and a sufficient signal to noise ratio, respectively. Here, we combine these requirements in a scheme for OCT-measurements with undetected photons based on nonlinear Ti:LiNbO$_3$ waveguides. We investigate the performance benchmarks of the commonly used SU(1,1) scheme in comparison to an induced coherence scheme and find that the latter is actually better suited when implementing measurements with undetected photons in integrated systems. In both schemes, we perform pump gain optimization and OCT measurements with undetected photons with an axial resolution as low as 28 $\mathrmμ$m. |
| title | Towards integrated sensors for optimized OCT with undetected photons |
| topic | Quantum Physics |
| url | https://arxiv.org/abs/2508.05320 |