Patient-Adaptive Echocardiography using Cognitive Ultrasound

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: van Nierop, Wessel L., Nolan, Oisín, Stevens, Tristan S. W., van Sloun, Ruud J. G.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913120851591168
author van Nierop, Wessel L.
Nolan, Oisín
Stevens, Tristan S. W.
van Sloun, Ruud J. G.
author_facet van Nierop, Wessel L.
Nolan, Oisín
Stevens, Tristan S. W.
van Sloun, Ruud J. G.
contents Focused transmits are the most commonly used transmit strategy for echocardiograms, but suffer from relatively low frame rates, and in 3D, even lower volume rates. Fast imaging based on unfocused transmits has disadvantages such as motion decorrelation and limited harmonic imaging capabilities. This work introduces a patient-adaptive focused transmit and receive scheme that has the ability to drastically reduce the number of transmits needed to produce a high-quality ultrasound image. The method relies on posterior sampling with a temporal diffusion model to perceive and reconstruct the anatomy based on partial observations, while subsequently acquiring the most informative transmits. This cognitive ultrasound modality outperforms random and equispaced subsampling in terms of distortion and perceptual metrics on the 2D EchoNet-Dynamic dataset and a 3D Philips dataset, where we actively select focused elevation planes. Furthermore, our method improves generalized contrast-to-noise ratio from 0.83 to 0.89 compared to the same number of diverging wave transmits on six in-house echocardiograms. Additionally, we can segment the left ventricle, with on average 0.91 Dice-Sørensen coefficient, through simulating using 2 out of 112 lines. Finally, our method can be run in real-time on GPU accelerators from 2023, increasing the maximum achievable frame-rate from 46 Hz to 58 Hz. The code is publicly available at https://tue-bmd.github.io/casl/.
format Preprint
id arxiv_https___arxiv_org_abs_2508_08782
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Patient-Adaptive Echocardiography using Cognitive Ultrasound
van Nierop, Wessel L.
Nolan, Oisín
Stevens, Tristan S. W.
van Sloun, Ruud J. G.
Signal Processing
Focused transmits are the most commonly used transmit strategy for echocardiograms, but suffer from relatively low frame rates, and in 3D, even lower volume rates. Fast imaging based on unfocused transmits has disadvantages such as motion decorrelation and limited harmonic imaging capabilities. This work introduces a patient-adaptive focused transmit and receive scheme that has the ability to drastically reduce the number of transmits needed to produce a high-quality ultrasound image. The method relies on posterior sampling with a temporal diffusion model to perceive and reconstruct the anatomy based on partial observations, while subsequently acquiring the most informative transmits. This cognitive ultrasound modality outperforms random and equispaced subsampling in terms of distortion and perceptual metrics on the 2D EchoNet-Dynamic dataset and a 3D Philips dataset, where we actively select focused elevation planes. Furthermore, our method improves generalized contrast-to-noise ratio from 0.83 to 0.89 compared to the same number of diverging wave transmits on six in-house echocardiograms. Additionally, we can segment the left ventricle, with on average 0.91 Dice-Sørensen coefficient, through simulating using 2 out of 112 lines. Finally, our method can be run in real-time on GPU accelerators from 2023, increasing the maximum achievable frame-rate from 46 Hz to 58 Hz. The code is publicly available at https://tue-bmd.github.io/casl/.
title Patient-Adaptive Echocardiography using Cognitive Ultrasound
topic Signal Processing
url https://arxiv.org/abs/2508.08782