Beam Cross Sections Create Mixtures: Improving Feature Localization in Secondary Electron Imaging

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Choudhary, Vaibhav, Agarwal, Akshay, Goyal, Vivek K
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911503742926848
author Choudhary, Vaibhav
Agarwal, Akshay
Goyal, Vivek K
author_facet Choudhary, Vaibhav
Agarwal, Akshay
Goyal, Vivek K
contents Secondary electron (SE) imaging techniques, such as scanning electron microscopy and helium ion microscopy (HIM), use electrons emitted by a sample in response to a focused beam of charged particles incident at a grid of raster scan positions. Spot size -- the diameter of the incident beam's spatial profile -- is one of the limiting factors for resolution, along with various sources of noise in the SE signal. The effect of the beam spatial profile is commonly understood as convolutional. We show that under a simple and plausible physical abstraction for the beam, though convolution describes the mean of the SE counts, the full distribution of SE counts is a mixture. We demonstrate that this more detailed modeling can enable resolution improvements over conventional estimators through a stylized application inspired by semiconductor inspection: localizing the edge in a two-valued sample. We derive Fisher information about edge location in conventional and time-resolved measurements (TRM) and also derive the maximum likelihood estimate (MLE) from the latter. Empirically, the MLE computed from TRM is approximately efficient except at very low beam diameter, so Fisher information comparisons are predictive of performance and can be used to optimize the beam diameter relative to the raster scan spacing. Monte Carlo simulations provide an example of the MLE giving a 5-fold reduction in root mean-squared error (RMSE) of edge localization as compared to conventional interpolation-based estimation. The RMSE is substantially below both the beam diameter and the raster scan spacing and thus sub-pixel localization is demonstrated. Applied to three real HIM datasets, the average RMSE reduction factor is 5.4.
format Preprint
id arxiv_https___arxiv_org_abs_2508_09942
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Beam Cross Sections Create Mixtures: Improving Feature Localization in Secondary Electron Imaging
Choudhary, Vaibhav
Agarwal, Akshay
Goyal, Vivek K
Signal Processing
Materials Science
Secondary electron (SE) imaging techniques, such as scanning electron microscopy and helium ion microscopy (HIM), use electrons emitted by a sample in response to a focused beam of charged particles incident at a grid of raster scan positions. Spot size -- the diameter of the incident beam's spatial profile -- is one of the limiting factors for resolution, along with various sources of noise in the SE signal. The effect of the beam spatial profile is commonly understood as convolutional. We show that under a simple and plausible physical abstraction for the beam, though convolution describes the mean of the SE counts, the full distribution of SE counts is a mixture. We demonstrate that this more detailed modeling can enable resolution improvements over conventional estimators through a stylized application inspired by semiconductor inspection: localizing the edge in a two-valued sample. We derive Fisher information about edge location in conventional and time-resolved measurements (TRM) and also derive the maximum likelihood estimate (MLE) from the latter. Empirically, the MLE computed from TRM is approximately efficient except at very low beam diameter, so Fisher information comparisons are predictive of performance and can be used to optimize the beam diameter relative to the raster scan spacing. Monte Carlo simulations provide an example of the MLE giving a 5-fold reduction in root mean-squared error (RMSE) of edge localization as compared to conventional interpolation-based estimation. The RMSE is substantially below both the beam diameter and the raster scan spacing and thus sub-pixel localization is demonstrated. Applied to three real HIM datasets, the average RMSE reduction factor is 5.4.
title Beam Cross Sections Create Mixtures: Improving Feature Localization in Secondary Electron Imaging
topic Signal Processing
Materials Science
url https://arxiv.org/abs/2508.09942