CleanCTG: A Deep Learning Model for Multi-Artefact Detection and Reconstruction in Cardiotocography

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Wong, Sheng, Albert, Beth, Jones, Gabriel Davis
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908490161717248
author Wong, Sheng
Albert, Beth
Jones, Gabriel Davis
author_facet Wong, Sheng
Albert, Beth
Jones, Gabriel Davis
contents Cardiotocography (CTG) is essential for fetal monitoring but is frequently compromised by diverse artefacts which obscure true fetal heart rate (FHR) patterns and can lead to misdiagnosis or delayed intervention. Current deep-learning approaches typically bypass comprehensive noise handling, applying minimal preprocessing or focusing solely on downstream classification, while traditional methods rely on simple interpolation or rule-based filtering that addresses only missing samples and fail to correct complex artefact types. We present CleanCTG, an end-to-end dual-stage model that first identifies multiple artefact types via multi-scale convolution and context-aware cross-attention, then reconstructs corrupted segments through artefact-specific correction branches. Training utilised over 800,000 minutes of physiologically realistic, synthetically corrupted CTGs derived from expert-verified "clean" recordings. On synthetic data, CleanCTG achieved perfect artefact detection (AU-ROC = 1.00) and reduced mean squared error (MSE) on corrupted segments to 2.74 x 10^-4 (clean-segment MSE = 2.40 x 10^-6), outperforming the next best method by more than 60%. External validation on 10,190 minutes of clinician-annotated segments yielded AU-ROC = 0.95 (sensitivity = 83.44%, specificity 94.22%), surpassing six comparator classifiers. Finally, when integrated with the Dawes-Redman system on 933 clinical CTG recordings, denoised traces increased specificity (from 80.70% to 82.70%) and shortened median time to decision by 33%. These findings suggest that explicit artefact removal and signal reconstruction can both maintain diagnostic accuracy and enable shorter monitoring sessions, offering a practical route to more reliable CTG interpretation.
format Preprint
id arxiv_https___arxiv_org_abs_2508_10928
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle CleanCTG: A Deep Learning Model for Multi-Artefact Detection and Reconstruction in Cardiotocography
Wong, Sheng
Albert, Beth
Jones, Gabriel Davis
Audio and Speech Processing
Machine Learning
Sound
Cardiotocography (CTG) is essential for fetal monitoring but is frequently compromised by diverse artefacts which obscure true fetal heart rate (FHR) patterns and can lead to misdiagnosis or delayed intervention. Current deep-learning approaches typically bypass comprehensive noise handling, applying minimal preprocessing or focusing solely on downstream classification, while traditional methods rely on simple interpolation or rule-based filtering that addresses only missing samples and fail to correct complex artefact types. We present CleanCTG, an end-to-end dual-stage model that first identifies multiple artefact types via multi-scale convolution and context-aware cross-attention, then reconstructs corrupted segments through artefact-specific correction branches. Training utilised over 800,000 minutes of physiologically realistic, synthetically corrupted CTGs derived from expert-verified "clean" recordings. On synthetic data, CleanCTG achieved perfect artefact detection (AU-ROC = 1.00) and reduced mean squared error (MSE) on corrupted segments to 2.74 x 10^-4 (clean-segment MSE = 2.40 x 10^-6), outperforming the next best method by more than 60%. External validation on 10,190 minutes of clinician-annotated segments yielded AU-ROC = 0.95 (sensitivity = 83.44%, specificity 94.22%), surpassing six comparator classifiers. Finally, when integrated with the Dawes-Redman system on 933 clinical CTG recordings, denoised traces increased specificity (from 80.70% to 82.70%) and shortened median time to decision by 33%. These findings suggest that explicit artefact removal and signal reconstruction can both maintain diagnostic accuracy and enable shorter monitoring sessions, offering a practical route to more reliable CTG interpretation.
title CleanCTG: A Deep Learning Model for Multi-Artefact Detection and Reconstruction in Cardiotocography
topic Audio and Speech Processing
Machine Learning
Sound
url https://arxiv.org/abs/2508.10928