High-Resolution Directional Depth Electrodes: Open-Source FEM Lead-Field Modeling, Characterization, and Validation

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Medani, Takfarinas, Willis, Jace, Wright, Chris, Vakilna, Yash, Shores, Ryan, Cassani, Raymundo, Joshi, Anand, Leahy, Richard, Seymour, John, Mosher, John
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912541713629184
author Medani, Takfarinas
Willis, Jace
Wright, Chris
Vakilna, Yash
Shores, Ryan
Cassani, Raymundo
Joshi, Anand
Leahy, Richard
Seymour, John
Mosher, John
author_facet Medani, Takfarinas
Willis, Jace
Wright, Chris
Vakilna, Yash
Shores, Ryan
Cassani, Raymundo
Joshi, Anand
Leahy, Richard
Seymour, John
Mosher, John
contents Depth electrodes used in stereoelectroencephalography (sEEG) and deep-brain stimulation (DBS) are essential tools for neural recording and stimulation. Traditional designs have limited spatial resolution, typically 8 to 16 cylindrical contacts (0.8 to 1.0 mm diameter) along a 5 to 10 cm shaft, restricting recordings from small or localized populations. Recent high-density, directional electrodes (HDsEEG) enable finer localization of local field potentials (LFPs) and spike timing. Yet, characterizing their directional sensitivity and validating modeling tools for lead field (LF) analysis remain critical. We compare finite element method (FEM) LF modeling of a novel HD-sEEG electrode using two tools: a commercial solver (ANSYS) and an open-source pipeline (Brainstorm-DUNEuro). Goals: (i) validate against analytical solutions, (ii) assess solver differences, and (iii) characterize HDsEEG directional sensitivity. LFs were modeled in simple and bio-relevant scenarios. Using Helmholtz reciprocity, we computed LFs by (a) electrode-based stimulation with ANSYS and (b) source-based recording with Brainstorm-DUNEuro. First, a multi-sphere head model with known solutions tested the solver's accuracy. Next, an HDsEEG electrode in a homogeneous conductor was simulated. Directional effects were assessed by comparing sensitivity with vs. without the insulating substrate. Source localization performance was also compared between HDsEEG and standard electrodes. Both solvers closely matched analytic solutions. In realistic settings, LF distributions were highly similar. Modeling showed clear directional sensitivity: contacts facing a source had higher sensitivity than those shadowed, reflecting a substrate shielding effect that vanished when the substrate was conductive. Crucially, HDsEEG improved source localization, as voltage differences across contacts provided robust directional LF information.
format Preprint
id arxiv_https___arxiv_org_abs_2508_13212
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle High-Resolution Directional Depth Electrodes: Open-Source FEM Lead-Field Modeling, Characterization, and Validation
Medani, Takfarinas
Willis, Jace
Wright, Chris
Vakilna, Yash
Shores, Ryan
Cassani, Raymundo
Joshi, Anand
Leahy, Richard
Seymour, John
Mosher, John
Medical Physics
Depth electrodes used in stereoelectroencephalography (sEEG) and deep-brain stimulation (DBS) are essential tools for neural recording and stimulation. Traditional designs have limited spatial resolution, typically 8 to 16 cylindrical contacts (0.8 to 1.0 mm diameter) along a 5 to 10 cm shaft, restricting recordings from small or localized populations. Recent high-density, directional electrodes (HDsEEG) enable finer localization of local field potentials (LFPs) and spike timing. Yet, characterizing their directional sensitivity and validating modeling tools for lead field (LF) analysis remain critical. We compare finite element method (FEM) LF modeling of a novel HD-sEEG electrode using two tools: a commercial solver (ANSYS) and an open-source pipeline (Brainstorm-DUNEuro). Goals: (i) validate against analytical solutions, (ii) assess solver differences, and (iii) characterize HDsEEG directional sensitivity. LFs were modeled in simple and bio-relevant scenarios. Using Helmholtz reciprocity, we computed LFs by (a) electrode-based stimulation with ANSYS and (b) source-based recording with Brainstorm-DUNEuro. First, a multi-sphere head model with known solutions tested the solver's accuracy. Next, an HDsEEG electrode in a homogeneous conductor was simulated. Directional effects were assessed by comparing sensitivity with vs. without the insulating substrate. Source localization performance was also compared between HDsEEG and standard electrodes. Both solvers closely matched analytic solutions. In realistic settings, LF distributions were highly similar. Modeling showed clear directional sensitivity: contacts facing a source had higher sensitivity than those shadowed, reflecting a substrate shielding effect that vanished when the substrate was conductive. Crucially, HDsEEG improved source localization, as voltage differences across contacts provided robust directional LF information.
title High-Resolution Directional Depth Electrodes: Open-Source FEM Lead-Field Modeling, Characterization, and Validation
topic Medical Physics
url https://arxiv.org/abs/2508.13212