Automated surgical planning with nnU-Net: delineation of the anatomy in hepatobiliary phase MRI

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Olthof, Karin A., Fusagli, Matteo, Güttner, Bianca, Natali, Tiziano, Westerink, Bram, Speidel, Stefanie, Ruers, Theo J. M., Kuhlmann, Koert F. D., Zhylka, Andrey
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866909744350887936
author Olthof, Karin A.
Fusagli, Matteo
Güttner, Bianca
Natali, Tiziano
Westerink, Bram
Speidel, Stefanie
Ruers, Theo J. M.
Kuhlmann, Koert F. D.
Zhylka, Andrey
author_facet Olthof, Karin A.
Fusagli, Matteo
Güttner, Bianca
Natali, Tiziano
Westerink, Bram
Speidel, Stefanie
Ruers, Theo J. M.
Kuhlmann, Koert F. D.
Zhylka, Andrey
contents Background: The aim of this study was to develop and evaluate a deep learning-based automated segmentation method for hepatic anatomy (i.e., parenchyma, tumors, portal vein, hepatic vein and biliary tree) from the hepatobiliary phase of gadoxetic acid-enhanced MRI. This method should ease the clinical workflow of preoperative planning. Methods: Manual segmentation was performed on hepatobiliary phase MRI scans from 90 consecutive patients who underwent liver surgery between January 2020 and October 2023. A deep learning network (nnU-Net v1) was trained on 72 patients with an extra focus on thin structures and topography preservation. Performance was evaluated on an 18-patient test set by comparing automated and manual segmentations using Dice similarity coefficient (DSC). Following clinical integration, 10 segmentations (assessment dataset) were generated using the network and manually refined for clinical use to quantify required adjustments using DSC. Results: In the test set, DSCs were 0.97+/-0.01 for liver parenchyma, 0.80+/-0.04 for hepatic vein, 0.79+/-0.07 for biliary tree, 0.77+/-0.17 for tumors, and 0.74+/-0.06 for portal vein. Average tumor detection rate was 76.6+/-24.1%, with a median of one false-positive per patient. The assessment dataset showed minor adjustments were required for clinical use of the 3D models, with high DSCs for parenchyma (1.00+/-0.00), portal vein (0.98+/-0.01) and hepatic vein (0.95+/-0.07). Tumor segmentation exhibited greater variability (DSC 0.80+/-0.27). During prospective clinical use, the model detected three additional tumors initially missed by radiologists. Conclusions: The proposed nnU-Net-based segmentation method enables accurate and automated delineation of hepatic anatomy. This enables 3D planning to be applied efficiently as a standard-of-care for every patient undergoing liver surgery.
format Preprint
id arxiv_https___arxiv_org_abs_2508_14133
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Automated surgical planning with nnU-Net: delineation of the anatomy in hepatobiliary phase MRI
Olthof, Karin A.
Fusagli, Matteo
Güttner, Bianca
Natali, Tiziano
Westerink, Bram
Speidel, Stefanie
Ruers, Theo J. M.
Kuhlmann, Koert F. D.
Zhylka, Andrey
Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Background: The aim of this study was to develop and evaluate a deep learning-based automated segmentation method for hepatic anatomy (i.e., parenchyma, tumors, portal vein, hepatic vein and biliary tree) from the hepatobiliary phase of gadoxetic acid-enhanced MRI. This method should ease the clinical workflow of preoperative planning. Methods: Manual segmentation was performed on hepatobiliary phase MRI scans from 90 consecutive patients who underwent liver surgery between January 2020 and October 2023. A deep learning network (nnU-Net v1) was trained on 72 patients with an extra focus on thin structures and topography preservation. Performance was evaluated on an 18-patient test set by comparing automated and manual segmentations using Dice similarity coefficient (DSC). Following clinical integration, 10 segmentations (assessment dataset) were generated using the network and manually refined for clinical use to quantify required adjustments using DSC. Results: In the test set, DSCs were 0.97+/-0.01 for liver parenchyma, 0.80+/-0.04 for hepatic vein, 0.79+/-0.07 for biliary tree, 0.77+/-0.17 for tumors, and 0.74+/-0.06 for portal vein. Average tumor detection rate was 76.6+/-24.1%, with a median of one false-positive per patient. The assessment dataset showed minor adjustments were required for clinical use of the 3D models, with high DSCs for parenchyma (1.00+/-0.00), portal vein (0.98+/-0.01) and hepatic vein (0.95+/-0.07). Tumor segmentation exhibited greater variability (DSC 0.80+/-0.27). During prospective clinical use, the model detected three additional tumors initially missed by radiologists. Conclusions: The proposed nnU-Net-based segmentation method enables accurate and automated delineation of hepatic anatomy. This enables 3D planning to be applied efficiently as a standard-of-care for every patient undergoing liver surgery.
title Automated surgical planning with nnU-Net: delineation of the anatomy in hepatobiliary phase MRI
topic Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2508.14133