Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Scheuren, Stefan, Millán-Callado, Maria Angeles, Kohl, Jonas, Jäger, Tim T., Roth, Markus, Rödel, Christian, Alejo, Aaron, Kroll, Florian, Zeil, Karl, Junghans, Arnd, Guerrero, Carlos, Schmitz, Benedikt
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908496184737792
author Scheuren, Stefan
Millán-Callado, Maria Angeles
Kohl, Jonas
Jäger, Tim T.
Roth, Markus
Rödel, Christian
Alejo, Aaron
Kroll, Florian
Zeil, Karl
Junghans, Arnd
Guerrero, Carlos
Schmitz, Benedikt
author_facet Scheuren, Stefan
Millán-Callado, Maria Angeles
Kohl, Jonas
Jäger, Tim T.
Roth, Markus
Rödel, Christian
Alejo, Aaron
Kroll, Florian
Zeil, Karl
Junghans, Arnd
Guerrero, Carlos
Schmitz, Benedikt
contents Bubble detectors are widely used to measure neutron flux from laser-driven sources employing a pitcher-catcher setup, due to their insensitivity to intense $γ$-ray backgrounds and strong electromagnetic pulses (EMP).\\ This paper presents a method to account for the neutron energy-dependent response of bubble detectors, enabling accurate conversion of bubble counts into neutron flux at the detector location. The proposed method is based on the accurate reconstruction of the response function using a surrogate model. The resulting model is convoluted with the (normalized) expected/measured neutron spectrum to obtain an effective measure of the bubble detector's response, herein referred to as effective $c$ or $c_\text{eff}$. This effective value for the response is energy-independent after the convolution. In this way, our approach includes the spectral distribution of neutrons arriving at the detector to determine the integral neutron flux. Analyzing our experimental results obtained at the DRACO PW laser and comparing the results to previously used methods to obtain neutron fluxes from bubble detectors returns a reduction in neutron flux of up to \SI{31}{\%}. Results from the method detailed in this paper agree with in-depth experimental setup Monte Carlo simulations, with deviations of less than \SI{10}{\%}. We furthermore discuss the inherent limitations of our method with regard to its uncertainty and highlight the influence of neutron scattering in bubble detector measurements. For our experimental setup at the DRACO laser, up to \SI{47}{\%} of the detected neutrons arrive at the detector after undergoing at least one scattering event.
format Preprint
id arxiv_https___arxiv_org_abs_2508_14463
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources
Scheuren, Stefan
Millán-Callado, Maria Angeles
Kohl, Jonas
Jäger, Tim T.
Roth, Markus
Rödel, Christian
Alejo, Aaron
Kroll, Florian
Zeil, Karl
Junghans, Arnd
Guerrero, Carlos
Schmitz, Benedikt
Instrumentation and Detectors
Nuclear Experiment
Bubble detectors are widely used to measure neutron flux from laser-driven sources employing a pitcher-catcher setup, due to their insensitivity to intense $γ$-ray backgrounds and strong electromagnetic pulses (EMP).\\ This paper presents a method to account for the neutron energy-dependent response of bubble detectors, enabling accurate conversion of bubble counts into neutron flux at the detector location. The proposed method is based on the accurate reconstruction of the response function using a surrogate model. The resulting model is convoluted with the (normalized) expected/measured neutron spectrum to obtain an effective measure of the bubble detector's response, herein referred to as effective $c$ or $c_\text{eff}$. This effective value for the response is energy-independent after the convolution. In this way, our approach includes the spectral distribution of neutrons arriving at the detector to determine the integral neutron flux. Analyzing our experimental results obtained at the DRACO PW laser and comparing the results to previously used methods to obtain neutron fluxes from bubble detectors returns a reduction in neutron flux of up to \SI{31}{\%}. Results from the method detailed in this paper agree with in-depth experimental setup Monte Carlo simulations, with deviations of less than \SI{10}{\%}. We furthermore discuss the inherent limitations of our method with regard to its uncertainty and highlight the influence of neutron scattering in bubble detector measurements. For our experimental setup at the DRACO laser, up to \SI{47}{\%} of the detected neutrons arrive at the detector after undergoing at least one scattering event.
title Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2508.14463