Stress-testing cross-cancer generalizability of 3D nnU-Net for PET-CT tumor segmentation: multi-cohort evaluation with novel oesophageal and lung cancer datasets

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ghosh, Soumen, Hannan, Christine Jestin, Vashistha, Rajat, Kundu, Parveen, Brosda, Sandra, Aoude, Lauren G., Lonie, James, Nathanson, Andrew, Ng, Jessica, Barbour, Andrew P., Vegh, Viktor
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866915463252934656
author Ghosh, Soumen
Hannan, Christine Jestin
Vashistha, Rajat
Kundu, Parveen
Brosda, Sandra
Aoude, Lauren G.
Lonie, James
Nathanson, Andrew
Ng, Jessica
Barbour, Andrew P.
Vegh, Viktor
author_facet Ghosh, Soumen
Hannan, Christine Jestin
Vashistha, Rajat
Kundu, Parveen
Brosda, Sandra
Aoude, Lauren G.
Lonie, James
Nathanson, Andrew
Ng, Jessica
Barbour, Andrew P.
Vegh, Viktor
contents Robust generalization is essential for deploying deep learning based tumor segmentation in clinical PET-CT workflows, where anatomical sites, scanners, and patient populations vary widely. This study presents the first cross cancer evaluation of nnU-Net on PET-CT, introducing two novel, expert-annotated whole-body datasets. 279 patients with oesophageal cancer (Australian cohort) and 54 with lung cancer (Indian cohort). These cohorts complement the public AutoPET dataset and enable systematic stress-testing of cross domain performance. We trained and tested 3D nnUNet models under three paradigms. Target only (oesophageal), public only (AutoPET), and combined training. For the tested sets, the oesophageal only model achieved the best in-domain accuracy (mean DSC, 57.8) but failed on external Indian lung cohort (mean DSC less than 3.4), indicating severe overfitting. The public only model generalized more broadly (mean DSC, 63.5 on AutoPET, 51.6 on Indian lung cohort) but underperformed in oesophageal Australian cohort (mean DSC, 26.7). The combined approach provided the most balanced results (mean DSC, lung (52.9), oesophageal (40.7), AutoPET (60.9)), reducing boundary errors and improving robustness across all cohorts. These findings demonstrate that dataset diversity, particularly multi demographic, multi center and multi cancer integration, outweighs architectural novelty as the key driver of robust generalization. This work presents the demography based cross cancer deep learning segmentation evaluation and highlights dataset diversity, rather than model complexity, as the foundation for clinically robust segmentation.
format Preprint
id arxiv_https___arxiv_org_abs_2508_18612
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Stress-testing cross-cancer generalizability of 3D nnU-Net for PET-CT tumor segmentation: multi-cohort evaluation with novel oesophageal and lung cancer datasets
Ghosh, Soumen
Hannan, Christine Jestin
Vashistha, Rajat
Kundu, Parveen
Brosda, Sandra
Aoude, Lauren G.
Lonie, James
Nathanson, Andrew
Ng, Jessica
Barbour, Andrew P.
Vegh, Viktor
Image and Video Processing
Machine Learning
Robust generalization is essential for deploying deep learning based tumor segmentation in clinical PET-CT workflows, where anatomical sites, scanners, and patient populations vary widely. This study presents the first cross cancer evaluation of nnU-Net on PET-CT, introducing two novel, expert-annotated whole-body datasets. 279 patients with oesophageal cancer (Australian cohort) and 54 with lung cancer (Indian cohort). These cohorts complement the public AutoPET dataset and enable systematic stress-testing of cross domain performance. We trained and tested 3D nnUNet models under three paradigms. Target only (oesophageal), public only (AutoPET), and combined training. For the tested sets, the oesophageal only model achieved the best in-domain accuracy (mean DSC, 57.8) but failed on external Indian lung cohort (mean DSC less than 3.4), indicating severe overfitting. The public only model generalized more broadly (mean DSC, 63.5 on AutoPET, 51.6 on Indian lung cohort) but underperformed in oesophageal Australian cohort (mean DSC, 26.7). The combined approach provided the most balanced results (mean DSC, lung (52.9), oesophageal (40.7), AutoPET (60.9)), reducing boundary errors and improving robustness across all cohorts. These findings demonstrate that dataset diversity, particularly multi demographic, multi center and multi cancer integration, outweighs architectural novelty as the key driver of robust generalization. This work presents the demography based cross cancer deep learning segmentation evaluation and highlights dataset diversity, rather than model complexity, as the foundation for clinically robust segmentation.
title Stress-testing cross-cancer generalizability of 3D nnU-Net for PET-CT tumor segmentation: multi-cohort evaluation with novel oesophageal and lung cancer datasets
topic Image and Video Processing
Machine Learning
url https://arxiv.org/abs/2508.18612