Sensing with Twisted Light: Precision Measurement of Fractional Azimuthal Index to Determine Refractive Index

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Perrella, Christopher, Punse, Aman Anil, Zalogina, Anastasiia, Szydzik, Crispin, Lim, Megan, Boes, Andreas, Mitchell, Arnan, Dunning, Kylie R., Dholakia, Kishan
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916920728485888
author Perrella, Christopher
Punse, Aman Anil
Zalogina, Anastasiia
Szydzik, Crispin
Lim, Megan
Boes, Andreas
Mitchell, Arnan
Dunning, Kylie R.
Dholakia, Kishan
author_facet Perrella, Christopher
Punse, Aman Anil
Zalogina, Anastasiia
Szydzik, Crispin
Lim, Megan
Boes, Andreas
Mitchell, Arnan
Dunning, Kylie R.
Dholakia, Kishan
contents Light beams possessing orbital angular momentum (OAM) have gained significant interest in areas such as optical manipulation, quantum entanglement, and super-resolved imaging. In itself, the OAM for a Laguerre-Gaussian beam is proportional to the azimuthal index of the light field, $l$. It is in fact continuous in nature and a non-trivial parameter to measure. The ability to determine $l$ precisely would broaden the use of such beams for new applications. In this study, we generate Laguerre-Gaussian beams of differing $l$ through mode conversion using microscopic spiral phase plates (SPPs). The exact value of $l$ imparted for a given incident wavelength is dependant upon the refractive index of the media within which the SPP is immersed. Here, we show an ultra-precise approach based on laser speckle to measure the azimuthal index of these generated beams to a precision of $2\,{\times}\,10^{-5}$. This is an improvement of three orders of magnitude over previous studies. In turn, this leverages an ultra-precise measurement of the refractive index of the medium surrounding the SPP, with a best measured precision of $6.4\,{\times}\,10^{-7}$\,refractive index units. This is confirmed to be at the shot-noise limit of the system. Our study interrogates samples of sucrose and haemoglobin, only 300\,pL in volume, within a microfluidic channel. This demonstration of an original form of microfluidic refractive index sensor, based on mode conversion to light fields with OAM, may be multiplexed to measure spatio-temporal variations and gradients within biological samples.
format Preprint
id arxiv_https___arxiv_org_abs_2508_19521
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Sensing with Twisted Light: Precision Measurement of Fractional Azimuthal Index to Determine Refractive Index
Perrella, Christopher
Punse, Aman Anil
Zalogina, Anastasiia
Szydzik, Crispin
Lim, Megan
Boes, Andreas
Mitchell, Arnan
Dunning, Kylie R.
Dholakia, Kishan
Optics
78-02
A.0
Light beams possessing orbital angular momentum (OAM) have gained significant interest in areas such as optical manipulation, quantum entanglement, and super-resolved imaging. In itself, the OAM for a Laguerre-Gaussian beam is proportional to the azimuthal index of the light field, $l$. It is in fact continuous in nature and a non-trivial parameter to measure. The ability to determine $l$ precisely would broaden the use of such beams for new applications. In this study, we generate Laguerre-Gaussian beams of differing $l$ through mode conversion using microscopic spiral phase plates (SPPs). The exact value of $l$ imparted for a given incident wavelength is dependant upon the refractive index of the media within which the SPP is immersed. Here, we show an ultra-precise approach based on laser speckle to measure the azimuthal index of these generated beams to a precision of $2\,{\times}\,10^{-5}$. This is an improvement of three orders of magnitude over previous studies. In turn, this leverages an ultra-precise measurement of the refractive index of the medium surrounding the SPP, with a best measured precision of $6.4\,{\times}\,10^{-7}$\,refractive index units. This is confirmed to be at the shot-noise limit of the system. Our study interrogates samples of sucrose and haemoglobin, only 300\,pL in volume, within a microfluidic channel. This demonstration of an original form of microfluidic refractive index sensor, based on mode conversion to light fields with OAM, may be multiplexed to measure spatio-temporal variations and gradients within biological samples.
title Sensing with Twisted Light: Precision Measurement of Fractional Azimuthal Index to Determine Refractive Index
topic Optics
78-02
A.0
url https://arxiv.org/abs/2508.19521