Data-Driven Bifurcation Handling in Physics-Based Reduced-Order Vascular Hemodynamic Models

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Rubio, Natalia L., Darve, Eric F., Marsden, Alison L.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915470035124224
author Rubio, Natalia L.
Darve, Eric F.
Marsden, Alison L.
author_facet Rubio, Natalia L.
Darve, Eric F.
Marsden, Alison L.
contents Three-dimensional (3D) finite-element simulations of cardiovascular flows provide high-fidelity predictions to support cardiovascular medicine, but their high computational cost limits clinical practicality. Reduced-order models (ROMs) offer computationally efficient alternatives but suffer reduced accuracy, particularly at vessel bifurcations where complex flow physics are inadequately captured by standard Poiseuille flow assumptions. We present an enhanced numerical framework that integrates machine learning-predicted bifurcation coefficients into zero-dimensional (0D) hemodynamic ROMs to improve accuracy while maintaining computational efficiency. We develop a resistor-resistor-inductor (RRI) model that uses neural networks to predict pressure-flow relationships from bifurcation geometry, incorporating linear and quadratic resistances along with inductive effects. The method employs non-dimensionalization to reduce training data requirements and apriori flow split prediction for improved bifurcation characterization. We incorporate the RRI model into a 0D model using an optimization-based solution strategy. We validate the approach in isolated bifurcations and vascular trees, across Reynolds numbers from 0 to 5,500, defining ROM accuracy by comparison to 3D finite element simulation. Results demonstrate substantial accuracy improvements: averaged across all trees and Reynolds numbers, the RRI method reduces inlet pressure errors from 54 mmHg (45%) for standard 0D models to 25 mmHg (17%), while a simplified resistor-inductor (RI) variant achieves 31 mmHg (26%) error. The enhanced 0D models show particular effectiveness at high Reynolds numbers and in extensive vascular networks. This hybrid numerical approach enables accurate, real-time hemodynamic modeling for clinical decision support, uncertainty quantification, and digital twins in cardiovascular biomedical engineering.
format Preprint
id arxiv_https___arxiv_org_abs_2508_21165
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Data-Driven Bifurcation Handling in Physics-Based Reduced-Order Vascular Hemodynamic Models
Rubio, Natalia L.
Darve, Eric F.
Marsden, Alison L.
Computational Engineering, Finance, and Science
Machine Learning
Numerical Analysis
76Z05
J.2
Three-dimensional (3D) finite-element simulations of cardiovascular flows provide high-fidelity predictions to support cardiovascular medicine, but their high computational cost limits clinical practicality. Reduced-order models (ROMs) offer computationally efficient alternatives but suffer reduced accuracy, particularly at vessel bifurcations where complex flow physics are inadequately captured by standard Poiseuille flow assumptions. We present an enhanced numerical framework that integrates machine learning-predicted bifurcation coefficients into zero-dimensional (0D) hemodynamic ROMs to improve accuracy while maintaining computational efficiency. We develop a resistor-resistor-inductor (RRI) model that uses neural networks to predict pressure-flow relationships from bifurcation geometry, incorporating linear and quadratic resistances along with inductive effects. The method employs non-dimensionalization to reduce training data requirements and apriori flow split prediction for improved bifurcation characterization. We incorporate the RRI model into a 0D model using an optimization-based solution strategy. We validate the approach in isolated bifurcations and vascular trees, across Reynolds numbers from 0 to 5,500, defining ROM accuracy by comparison to 3D finite element simulation. Results demonstrate substantial accuracy improvements: averaged across all trees and Reynolds numbers, the RRI method reduces inlet pressure errors from 54 mmHg (45%) for standard 0D models to 25 mmHg (17%), while a simplified resistor-inductor (RI) variant achieves 31 mmHg (26%) error. The enhanced 0D models show particular effectiveness at high Reynolds numbers and in extensive vascular networks. This hybrid numerical approach enables accurate, real-time hemodynamic modeling for clinical decision support, uncertainty quantification, and digital twins in cardiovascular biomedical engineering.
title Data-Driven Bifurcation Handling in Physics-Based Reduced-Order Vascular Hemodynamic Models
topic Computational Engineering, Finance, and Science
Machine Learning
Numerical Analysis
76Z05
J.2
url https://arxiv.org/abs/2508.21165