Lightweight MRI-Based Automated Segmentation of Pancreatic Cancer with Auto3DSeg

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Jha, Keshav, Sharp, William, LaBella, Dominic
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918132503805952
author Jha, Keshav
Sharp, William
LaBella, Dominic
author_facet Jha, Keshav
Sharp, William
LaBella, Dominic
contents Accurate delineation of pancreatic tumors is critical for diagnosis, treatment planning, and outcome assessment, yet automated segmentation remains challenging due to anatomical variability and limited dataset availability. In this study, SegResNet models, as part of the Auto3DSeg architecture, were trained and evaluated on two MRI-based pancreatic tumor segmentation tasks as part of the 2025 PANTHER Challenge. Algorithm methodology included 5-fold cross-validation with STAPLE ensembling after focusing on an anatomically relevant region-of-interest. The Pancreatic Tumor Segmentation on Diagnostic MRI task 1 training set included 91 T1-weighted arterial contrast-enhanced MRI with expert annotated pancreas and tumor labels. The Pancreatic Tumor Segmentation on MR-Linac task 2 training set used 50 T2-weighted MR-Linac cases with expert annotated pancreas and tumor labels. Algorithm-automated segmentation performance of pancreatic tumor was assessed using Dice Similarity Coefficient (DSC), 5 mm DSC, 95th percentile Hausdorff Distance (HD95), Mean Average Surface Distance (MASD), and Root Mean Square Error (RMSE). For Task 1, the algorithm achieved a DSC of 0.56, 5 mm DSC of 0.73, HD95 of 41.1 mm, MASD of 26.0 mm, and RMSE of 5164 mm. For Task 2, performance decreased, with a DSC of 0.33, 5 mm DSC of 0.50, HD95 of 20.1 mm, MASD of 7.2 mm, and RMSE of 17,203 mm. These findings illustrate the challenges of MRI-based pancreatic tumor segmentation with small datasets, highlighting variability introduced by different MRI sequences. Despite modest performance, the results demonstrate potential for automated delineation and emphasize the need for larger, standardized MRI datasets to improve model robustness and clinical utility.
format Preprint
id arxiv_https___arxiv_org_abs_2508_21227
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Lightweight MRI-Based Automated Segmentation of Pancreatic Cancer with Auto3DSeg
Jha, Keshav
Sharp, William
LaBella, Dominic
Computer Vision and Pattern Recognition
68T07, 68U10
I.4.6; I.5.4; J.3
Accurate delineation of pancreatic tumors is critical for diagnosis, treatment planning, and outcome assessment, yet automated segmentation remains challenging due to anatomical variability and limited dataset availability. In this study, SegResNet models, as part of the Auto3DSeg architecture, were trained and evaluated on two MRI-based pancreatic tumor segmentation tasks as part of the 2025 PANTHER Challenge. Algorithm methodology included 5-fold cross-validation with STAPLE ensembling after focusing on an anatomically relevant region-of-interest. The Pancreatic Tumor Segmentation on Diagnostic MRI task 1 training set included 91 T1-weighted arterial contrast-enhanced MRI with expert annotated pancreas and tumor labels. The Pancreatic Tumor Segmentation on MR-Linac task 2 training set used 50 T2-weighted MR-Linac cases with expert annotated pancreas and tumor labels. Algorithm-automated segmentation performance of pancreatic tumor was assessed using Dice Similarity Coefficient (DSC), 5 mm DSC, 95th percentile Hausdorff Distance (HD95), Mean Average Surface Distance (MASD), and Root Mean Square Error (RMSE). For Task 1, the algorithm achieved a DSC of 0.56, 5 mm DSC of 0.73, HD95 of 41.1 mm, MASD of 26.0 mm, and RMSE of 5164 mm. For Task 2, performance decreased, with a DSC of 0.33, 5 mm DSC of 0.50, HD95 of 20.1 mm, MASD of 7.2 mm, and RMSE of 17,203 mm. These findings illustrate the challenges of MRI-based pancreatic tumor segmentation with small datasets, highlighting variability introduced by different MRI sequences. Despite modest performance, the results demonstrate potential for automated delineation and emphasize the need for larger, standardized MRI datasets to improve model robustness and clinical utility.
title Lightweight MRI-Based Automated Segmentation of Pancreatic Cancer with Auto3DSeg
topic Computer Vision and Pattern Recognition
68T07, 68U10
I.4.6; I.5.4; J.3
url https://arxiv.org/abs/2508.21227