An Evaluation of External Magnetic Flux Error in Magnet-Moving Kibble balances

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Ma, Yongchao, Zhao, Wei, Huang, Songling, Li, Shisong
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916925286645760
author Ma, Yongchao
Zhao, Wei
Huang, Songling
Li, Shisong
author_facet Ma, Yongchao
Zhao, Wei
Huang, Songling
Li, Shisong
contents The magnet-moving measurement scheme in Kibble balances avoids displacing force-sensitive components, such as the weighing cell, and enables a broader magnetic profile measurement range during the velocity phase. However, this mechanism introduces the risk of asymmetry in the $Bl$ measurement due to external magnetic flux, leading to a potential systematic error in the final measurement results. Using the Tsinghua tabletop Kibble balance magnet as a case study, this paper investigates the error mechanism through finite element analysis and experimental investigations. An evaluation method combining external weak-field measurements with attenuation factor analysis is proposed to assess external magnetic flux errors in magnet-moving measurement schemes. The findings demonstrate that selecting an optimal weighing position can reduce the far-end flux effect to the order of $10^{-9}$. In contrast, the near-end flux effect can be quantified by monitoring the magnetic field surrounding the magnet system. In the Tsinghua Kibble balance system, we show that with proper control of external flux sources, the relative error can be reduced below $1 \times 10^{-8}$ without requiring additional magnetic shielding.
format Preprint
id arxiv_https___arxiv_org_abs_2508_21604
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle An Evaluation of External Magnetic Flux Error in Magnet-Moving Kibble balances
Ma, Yongchao
Zhao, Wei
Huang, Songling
Li, Shisong
Instrumentation and Detectors
The magnet-moving measurement scheme in Kibble balances avoids displacing force-sensitive components, such as the weighing cell, and enables a broader magnetic profile measurement range during the velocity phase. However, this mechanism introduces the risk of asymmetry in the $Bl$ measurement due to external magnetic flux, leading to a potential systematic error in the final measurement results. Using the Tsinghua tabletop Kibble balance magnet as a case study, this paper investigates the error mechanism through finite element analysis and experimental investigations. An evaluation method combining external weak-field measurements with attenuation factor analysis is proposed to assess external magnetic flux errors in magnet-moving measurement schemes. The findings demonstrate that selecting an optimal weighing position can reduce the far-end flux effect to the order of $10^{-9}$. In contrast, the near-end flux effect can be quantified by monitoring the magnetic field surrounding the magnet system. In the Tsinghua Kibble balance system, we show that with proper control of external flux sources, the relative error can be reduced below $1 \times 10^{-8}$ without requiring additional magnetic shielding.
title An Evaluation of External Magnetic Flux Error in Magnet-Moving Kibble balances
topic Instrumentation and Detectors
url https://arxiv.org/abs/2508.21604