A semi-analytical approach to characterize high-frequency three-dimensional wave propagation through clamp-on flowmeters

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Valappil, Sabiju Valiya, Aragon, Alejandro M., Goosen, Johannes F. L.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918132838301696
author Valappil, Sabiju Valiya
Aragon, Alejandro M.
Goosen, Johannes F. L.
author_facet Valappil, Sabiju Valiya
Aragon, Alejandro M.
Goosen, Johannes F. L.
contents Wave propagation analysis at high frequencies is essential for applications involving ultrasound waves, such as clamp-on ultrasonic flowmeters. However, it is extremely challenging to perform a 3D transient analysis of a clamp-on flowmeter using standard tools such as finite element analysis (FEA) due to the enormous associated computational cost. In this study, we separate the clamp-on flowmeter into different domains and analyze them separately. Wave propagation in the fluid domain is analyzed via FEA at low frequencies (100 kHz, 200 kHz, and 500 kHz) and using ray tracing at high frequencies (1 MHz). The behavior in the solid domain (wedges and pipe wall) is analytically characterized via geometric projection. All these individual analyses provide us with different scaling factors with which the waves in the respective domains scale when 3D effects are considered. The complete clamp-on system is then analyzed in 2D via the Discontinuous Galerkin (DG) method to obtain the response at the receiver. The receiving signal is then scaled using the aforementioned scaling factors to accurately capture the wave propagation behavior of the clamp-on system in 3D. The output signal from the 2D analysis then becomes much clearer so that the fluid signal can be identified straightforwardly, which would be nearly impossible otherwise.
format Preprint
id arxiv_https___arxiv_org_abs_2509_00020
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A semi-analytical approach to characterize high-frequency three-dimensional wave propagation through clamp-on flowmeters
Valappil, Sabiju Valiya
Aragon, Alejandro M.
Goosen, Johannes F. L.
Fluid Dynamics
Numerical Analysis
Wave propagation analysis at high frequencies is essential for applications involving ultrasound waves, such as clamp-on ultrasonic flowmeters. However, it is extremely challenging to perform a 3D transient analysis of a clamp-on flowmeter using standard tools such as finite element analysis (FEA) due to the enormous associated computational cost. In this study, we separate the clamp-on flowmeter into different domains and analyze them separately. Wave propagation in the fluid domain is analyzed via FEA at low frequencies (100 kHz, 200 kHz, and 500 kHz) and using ray tracing at high frequencies (1 MHz). The behavior in the solid domain (wedges and pipe wall) is analytically characterized via geometric projection. All these individual analyses provide us with different scaling factors with which the waves in the respective domains scale when 3D effects are considered. The complete clamp-on system is then analyzed in 2D via the Discontinuous Galerkin (DG) method to obtain the response at the receiver. The receiving signal is then scaled using the aforementioned scaling factors to accurately capture the wave propagation behavior of the clamp-on system in 3D. The output signal from the 2D analysis then becomes much clearer so that the fluid signal can be identified straightforwardly, which would be nearly impossible otherwise.
title A semi-analytical approach to characterize high-frequency three-dimensional wave propagation through clamp-on flowmeters
topic Fluid Dynamics
Numerical Analysis
url https://arxiv.org/abs/2509.00020