Radial spoke energy for self-navigated motion detection and position-ordered dynamic musculoskeletal MRI

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lin, Enping, Calakli, Fatih, Arslan, Musa Tunç, Farina, Giovani Schulte, Warfield, Simon Keith
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866909822398496768
author Lin, Enping
Calakli, Fatih
Arslan, Musa Tunç
Farina, Giovani Schulte
Warfield, Simon Keith
author_facet Lin, Enping
Calakli, Fatih
Arslan, Musa Tunç
Farina, Giovani Schulte
Warfield, Simon Keith
contents Motion remains a key challenge in MRI, as both involuntary (e.g., head motion) and voluntary (e.g., joint motion) movement can degrade image quality or provide opportunities for dynamic assessment. Existing motion sensing methods, such as external tracking or navigator sequences, often require additional hardware, increase SAR, or demand sequence modification, which limits clinical flexibility. We propose a computationally efficient, self-navigated motion sensing technique based on spoke energy derived from 3D radial k-space data. Using the Fourier Slice and Parseval's theorems, spoke energy captures object-coil alignment and can be computed without altering the sequence. A sliding window summation improves robustness, and a second principal component analysis (2ndPCA) strategy yields a unified motion-sensitive signal. Beyond conventional head motion correction, we demonstrate the novel application of this method in enhancing dynamic 4D MRI of the ankle and knee under a continuous movement protocol. By sorting spokes based on position rather than time, we achieve motion-resolved reconstructions with improved anatomical clarity. This approach enables real-time motion detection and supports broader adoption of motion-aware dynamic MRI.
format Preprint
id arxiv_https___arxiv_org_abs_2509_01833
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Radial spoke energy for self-navigated motion detection and position-ordered dynamic musculoskeletal MRI
Lin, Enping
Calakli, Fatih
Arslan, Musa Tunç
Farina, Giovani Schulte
Warfield, Simon Keith
Medical Physics
Motion remains a key challenge in MRI, as both involuntary (e.g., head motion) and voluntary (e.g., joint motion) movement can degrade image quality or provide opportunities for dynamic assessment. Existing motion sensing methods, such as external tracking or navigator sequences, often require additional hardware, increase SAR, or demand sequence modification, which limits clinical flexibility. We propose a computationally efficient, self-navigated motion sensing technique based on spoke energy derived from 3D radial k-space data. Using the Fourier Slice and Parseval's theorems, spoke energy captures object-coil alignment and can be computed without altering the sequence. A sliding window summation improves robustness, and a second principal component analysis (2ndPCA) strategy yields a unified motion-sensitive signal. Beyond conventional head motion correction, we demonstrate the novel application of this method in enhancing dynamic 4D MRI of the ankle and knee under a continuous movement protocol. By sorting spokes based on position rather than time, we achieve motion-resolved reconstructions with improved anatomical clarity. This approach enables real-time motion detection and supports broader adoption of motion-aware dynamic MRI.
title Radial spoke energy for self-navigated motion detection and position-ordered dynamic musculoskeletal MRI
topic Medical Physics
url https://arxiv.org/abs/2509.01833