A Computational Pipeline for Patient-Specific Modeling of Thoracic Aortic Aneurysm: From Medical Image to Finite Element Analysis

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Chen, Jiasong, Qian, Linchen, Gong, Ruonan, Sun, Christina, Qin, Tongran, Pham, Thuy, Martin, Caitlin, Zafar, Mohammad, Elefteriades, John, Sun, Wei, Liang, Liang
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866908540991438848
author Chen, Jiasong
Qian, Linchen
Gong, Ruonan
Sun, Christina
Qin, Tongran
Pham, Thuy
Martin, Caitlin
Zafar, Mohammad
Elefteriades, John
Sun, Wei
Liang, Liang
author_facet Chen, Jiasong
Qian, Linchen
Gong, Ruonan
Sun, Christina
Qin, Tongran
Pham, Thuy
Martin, Caitlin
Zafar, Mohammad
Elefteriades, John
Sun, Wei
Liang, Liang
contents The aorta is the body's largest arterial vessel, serving as the primary pathway for oxygenated blood within the systemic circulation. Aortic aneurysms consistently rank among the top twenty causes of mortality in the United States. Thoracic aortic aneurysm (TAA) arises from abnormal dilation of the thoracic aorta and remains a clinically significant disease, ranking as one of the leading causes of death in adults. A thoracic aortic aneurysm ruptures when the integrity of all aortic wall layers is compromised due to elevated blood pressure. Currently, three-dimensional computed tomography (3D CT) is considered the gold standard for diagnosing TAA. The geometric characteristics of the aorta, which can be quantified from medical imaging, and stresses on the aortic wall, which can be obtained by finite element analysis (FEA), are critical in evaluating the risk of rupture and dissection. Deep learning based image segmentation has emerged as a reliable method for extracting anatomical regions of interest from medical images. Voxel based segmentation masks of anatomical structures are typically converted into structured mesh representation to enable accurate simulation. Hexahedral meshes are commonly used in finite element simulations of the aorta due to their computational efficiency and superior simulation accuracy. Due to anatomical variability, patient specific modeling enables detailed assessment of individual anatomical and biomechanics behaviors, supporting precise simulations, accurate diagnoses, and personalized treatment strategies. Finite element (FE) simulations provide valuable insights into the biomechanical behaviors of tissues and organs in clinical studies. Developing accurate FE models represents a crucial initial step in establishing a patient-specific, biomechanically based framework for predicting the risk of TAA.
format Preprint
id arxiv_https___arxiv_org_abs_2509_12596
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A Computational Pipeline for Patient-Specific Modeling of Thoracic Aortic Aneurysm: From Medical Image to Finite Element Analysis
Chen, Jiasong
Qian, Linchen
Gong, Ruonan
Sun, Christina
Qin, Tongran
Pham, Thuy
Martin, Caitlin
Zafar, Mohammad
Elefteriades, John
Sun, Wei
Liang, Liang
Image and Video Processing
Computational Engineering, Finance, and Science
The aorta is the body's largest arterial vessel, serving as the primary pathway for oxygenated blood within the systemic circulation. Aortic aneurysms consistently rank among the top twenty causes of mortality in the United States. Thoracic aortic aneurysm (TAA) arises from abnormal dilation of the thoracic aorta and remains a clinically significant disease, ranking as one of the leading causes of death in adults. A thoracic aortic aneurysm ruptures when the integrity of all aortic wall layers is compromised due to elevated blood pressure. Currently, three-dimensional computed tomography (3D CT) is considered the gold standard for diagnosing TAA. The geometric characteristics of the aorta, which can be quantified from medical imaging, and stresses on the aortic wall, which can be obtained by finite element analysis (FEA), are critical in evaluating the risk of rupture and dissection. Deep learning based image segmentation has emerged as a reliable method for extracting anatomical regions of interest from medical images. Voxel based segmentation masks of anatomical structures are typically converted into structured mesh representation to enable accurate simulation. Hexahedral meshes are commonly used in finite element simulations of the aorta due to their computational efficiency and superior simulation accuracy. Due to anatomical variability, patient specific modeling enables detailed assessment of individual anatomical and biomechanics behaviors, supporting precise simulations, accurate diagnoses, and personalized treatment strategies. Finite element (FE) simulations provide valuable insights into the biomechanical behaviors of tissues and organs in clinical studies. Developing accurate FE models represents a crucial initial step in establishing a patient-specific, biomechanically based framework for predicting the risk of TAA.
title A Computational Pipeline for Patient-Specific Modeling of Thoracic Aortic Aneurysm: From Medical Image to Finite Element Analysis
topic Image and Video Processing
Computational Engineering, Finance, and Science
url https://arxiv.org/abs/2509.12596