Oakridge PPU Magnets: Results and Measurements

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: DiMarco, J., Harding, D., Kashikhin, V., Kiemschies, O., Kifarkis, M., Makulski, A., Nogiec, J., Stoynev, S., Strauss, T., Tartaglia, M., Thompson, P.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909791798951936
author DiMarco, J.
Harding, D.
Kashikhin, V.
Kiemschies, O.
Kifarkis, M.
Makulski, A.
Nogiec, J.
Stoynev, S.
Strauss, T.
Tartaglia, M.
Thompson, P.
author_facet DiMarco, J.
Harding, D.
Kashikhin, V.
Kiemschies, O.
Kifarkis, M.
Makulski, A.
Nogiec, J.
Stoynev, S.
Strauss, T.
Tartaglia, M.
Thompson, P.
contents The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is being upgraded from 1.0 GeV to 1.3 GeV (or 1.4 to 2.8 MW). Several water-cooled magnets have been upgraded to transport 30% higher beam energy. Fermilab contributed the magnet design for the new chicane magnets and injection/extraction septum. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field so as not to disturb the circulating beam. After fabrication of the magnets, an extensive measurement campaign was developed and performed at Fermilab's Magnet Test Facility. The measurements needed to assess magnet performance and provide comparison to design calculations. These included verification of field strength and harmonics along an 8 m length and 200 mm good field diameter for the chicane dipoles, end-field Hall probe mapping of these magnets, and measurements along two differently curved trajectories within the ~3 m septum gradient magnet. Details of the measurements and systems are presented along with results and comparison to field models.
format Preprint
id arxiv_https___arxiv_org_abs_2509_13455
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Oakridge PPU Magnets: Results and Measurements
DiMarco, J.
Harding, D.
Kashikhin, V.
Kiemschies, O.
Kifarkis, M.
Makulski, A.
Nogiec, J.
Stoynev, S.
Strauss, T.
Tartaglia, M.
Thompson, P.
Accelerator Physics
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is being upgraded from 1.0 GeV to 1.3 GeV (or 1.4 to 2.8 MW). Several water-cooled magnets have been upgraded to transport 30% higher beam energy. Fermilab contributed the magnet design for the new chicane magnets and injection/extraction septum. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field so as not to disturb the circulating beam. After fabrication of the magnets, an extensive measurement campaign was developed and performed at Fermilab's Magnet Test Facility. The measurements needed to assess magnet performance and provide comparison to design calculations. These included verification of field strength and harmonics along an 8 m length and 200 mm good field diameter for the chicane dipoles, end-field Hall probe mapping of these magnets, and measurements along two differently curved trajectories within the ~3 m septum gradient magnet. Details of the measurements and systems are presented along with results and comparison to field models.
title Oakridge PPU Magnets: Results and Measurements
topic Accelerator Physics
url https://arxiv.org/abs/2509.13455