Measurement of radiant spectrum for excess heat generation in NiCu and Ni thin film during hydrogen gas desorption

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Kasagi, J., Itoh, T., Shibasaki, Y., Iwamura, Y.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916954557644800
author Kasagi, J.
Itoh, T.
Shibasaki, Y.
Iwamura, Y.
author_facet Kasagi, J.
Itoh, T.
Shibasaki, Y.
Iwamura, Y.
contents Heat production in Ni-based thin films interacting with hydrogen gas was studied using a radiation calorimeter equipped with a composite photon-detector system. Measurements were performed on pure Ni foil and NiCu composite thin films. Electromagnetic radiation emitted from samples heated to approximately 1100 K in vacuum was recorded over the energy range of 0.05 - 2.5 eV. In this study,detailed spectra were obtained, particularly in the low-energy region below 0.5 eV. The peak of the thermal radiation spectrum was observed around 0.2 eV, deviating from that expected for simple graybody radiation. Spectral variations depending on the presence or absence of hydrogen differed between the NiCu and pure Ni samples. The total radiated energy was determined directly from the measured radiation power, without relying on radiation models. The excess heat generated in the NiCu sample was estimated to be approximately 1.1 W. A comparable but slightly smaller excess heat generation was also observed in Ni. Long-term measurements of the NiCu sample demonstrated sustained excess heat production for at least 215 hours, with a decay time exceeding 2000 hours.
format Preprint
id arxiv_https___arxiv_org_abs_2509_13847
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Measurement of radiant spectrum for excess heat generation in NiCu and Ni thin film during hydrogen gas desorption
Kasagi, J.
Itoh, T.
Shibasaki, Y.
Iwamura, Y.
Instrumentation and Detectors
Heat production in Ni-based thin films interacting with hydrogen gas was studied using a radiation calorimeter equipped with a composite photon-detector system. Measurements were performed on pure Ni foil and NiCu composite thin films. Electromagnetic radiation emitted from samples heated to approximately 1100 K in vacuum was recorded over the energy range of 0.05 - 2.5 eV. In this study,detailed spectra were obtained, particularly in the low-energy region below 0.5 eV. The peak of the thermal radiation spectrum was observed around 0.2 eV, deviating from that expected for simple graybody radiation. Spectral variations depending on the presence or absence of hydrogen differed between the NiCu and pure Ni samples. The total radiated energy was determined directly from the measured radiation power, without relying on radiation models. The excess heat generated in the NiCu sample was estimated to be approximately 1.1 W. A comparable but slightly smaller excess heat generation was also observed in Ni. Long-term measurements of the NiCu sample demonstrated sustained excess heat production for at least 215 hours, with a decay time exceeding 2000 hours.
title Measurement of radiant spectrum for excess heat generation in NiCu and Ni thin film during hydrogen gas desorption
topic Instrumentation and Detectors
url https://arxiv.org/abs/2509.13847