Supersonic gas curtain based real-time ionization profile monitor for hadron therapy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Kumar, Narender, Patel, Milaan, Butcher, William, Zhang, Hao, Stringer, Oliver, Wolfenden, Joseph, Welsch, Carsten P
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915501317292032
author Kumar, Narender
Patel, Milaan
Butcher, William
Zhang, Hao
Stringer, Oliver
Wolfenden, Joseph
Welsch, Carsten P
author_facet Kumar, Narender
Patel, Milaan
Butcher, William
Zhang, Hao
Stringer, Oliver
Wolfenden, Joseph
Welsch, Carsten P
contents Accurate control and monitoring of the beam is essential for precise dose delivery to tumor tissues during radiotherapy. Real-time monitoring of ion beam profiles and positions improves beam control, patient safety, and treatment reliability by providing immediate feedback. This becomes even more critical in FLASH therapy, where the short corrective window during high-dose delivery demands precise beam control. Existing devices are often limited to in vitro calibration or focus on monitoring a single parameter during treatment. This study aims to develop a device that can simultaneously monitor beam position, profile, current, and energy in real-time, without perturbing the beam, using a supersonic gas curtain system. A supersonic gas curtain beam profile monitor was developed at the Cockcroft Institute to assess its performance and suitability for applications in hadron-beam therapy. The system was integrated with one of the beamlines of the Pelletron accelerator at the Dalton Cumbrian Facility, UK and 2D profile measurements of carbon beams were conducted. The monitor successfully measured the beam profiles within 100ms to 1s across various beam currents (1 - 100 nA), energies (12 - 24 MeV), and charge states (2-5) of carbon. Recorded data was used to estimate detector performance by introducing a parameter called detection limit to quantify sensitivity of the monitor, identifying the threshold number of ions required for detection onset. A method to quantify sensitivity under different beam conditions is then discussed in detail, illustrated with an example case of FLASH beam parameters. This proof-of-concept study demonstrates the performance of the gas curtain-based ionization profile monitor for 2D transverse beam profile measurement of carbon ions. The sensitivity is quantified and evaluated against an example case for FLASH conditions.
format Preprint
id arxiv_https___arxiv_org_abs_2509_14892
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Supersonic gas curtain based real-time ionization profile monitor for hadron therapy
Kumar, Narender
Patel, Milaan
Butcher, William
Zhang, Hao
Stringer, Oliver
Wolfenden, Joseph
Welsch, Carsten P
Accelerator Physics
Accurate control and monitoring of the beam is essential for precise dose delivery to tumor tissues during radiotherapy. Real-time monitoring of ion beam profiles and positions improves beam control, patient safety, and treatment reliability by providing immediate feedback. This becomes even more critical in FLASH therapy, where the short corrective window during high-dose delivery demands precise beam control. Existing devices are often limited to in vitro calibration or focus on monitoring a single parameter during treatment. This study aims to develop a device that can simultaneously monitor beam position, profile, current, and energy in real-time, without perturbing the beam, using a supersonic gas curtain system. A supersonic gas curtain beam profile monitor was developed at the Cockcroft Institute to assess its performance and suitability for applications in hadron-beam therapy. The system was integrated with one of the beamlines of the Pelletron accelerator at the Dalton Cumbrian Facility, UK and 2D profile measurements of carbon beams were conducted. The monitor successfully measured the beam profiles within 100ms to 1s across various beam currents (1 - 100 nA), energies (12 - 24 MeV), and charge states (2-5) of carbon. Recorded data was used to estimate detector performance by introducing a parameter called detection limit to quantify sensitivity of the monitor, identifying the threshold number of ions required for detection onset. A method to quantify sensitivity under different beam conditions is then discussed in detail, illustrated with an example case of FLASH beam parameters. This proof-of-concept study demonstrates the performance of the gas curtain-based ionization profile monitor for 2D transverse beam profile measurement of carbon ions. The sensitivity is quantified and evaluated against an example case for FLASH conditions.
title Supersonic gas curtain based real-time ionization profile monitor for hadron therapy
topic Accelerator Physics
url https://arxiv.org/abs/2509.14892