contents To address the variability of renewable generation, initiatives have been launched globally to provide faster and more effective frequency responses. In the UK, the National Energy System Operator (NESO) has introduced a suite of three new dynamic services, where aggregation of assets is expected to play a key role. For an Aggregated Response Unit (ARU), the required level of frequency response varies with grid frequency, resulting in a frequency-varying equality constraint that assets should meet collectively. We show that the optimal coordination of an ARU constitutes a Frequency-Varying Optimization (FVO) problem, in which the optimal trajectory for each asset evolves dynamically. To facilitate online optimization, we reformulate the FVO problem into Tracking of the Optimal Trajectory (TOT) problems, with algorithms proposed for two scenarios: one where the asset dynamics are negligible, and another where they must be accounted for. Under reasonable conditions, the ARU converges to the optimal trajectory within a fixed time, and within the maximum delivery time requested by NESO. The proposed framework can be readily distributed to coordinate a large number of assets. Numerical results verify the effectiveness and scalability of the proposed control framework.
format Preprint
id arxiv_https___arxiv_org_abs_2509_18935
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Frequency-Varying Optimization: A Control Framework for New Dynamic Frequency Response Services
Xu, Yiqiao
Wan, Quan
Parisio, Alessandra
Systems and Control
To address the variability of renewable generation, initiatives have been launched globally to provide faster and more effective frequency responses. In the UK, the National Energy System Operator (NESO) has introduced a suite of three new dynamic services, where aggregation of assets is expected to play a key role. For an Aggregated Response Unit (ARU), the required level of frequency response varies with grid frequency, resulting in a frequency-varying equality constraint that assets should meet collectively. We show that the optimal coordination of an ARU constitutes a Frequency-Varying Optimization (FVO) problem, in which the optimal trajectory for each asset evolves dynamically. To facilitate online optimization, we reformulate the FVO problem into Tracking of the Optimal Trajectory (TOT) problems, with algorithms proposed for two scenarios: one where the asset dynamics are negligible, and another where they must be accounted for. Under reasonable conditions, the ARU converges to the optimal trajectory within a fixed time, and within the maximum delivery time requested by NESO. The proposed framework can be readily distributed to coordinate a large number of assets. Numerical results verify the effectiveness and scalability of the proposed control framework.