Digital Twins of Mechanically Ventilated Preterm Neonates with Respiratory Distress Syndrome

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Saffaran, Sina, Kwok, Tng Chang, Sharkey, Don, Bates, Declan G.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911172007034880
author Saffaran, Sina
Kwok, Tng Chang
Sharkey, Don
Bates, Declan G.
author_facet Saffaran, Sina
Kwok, Tng Chang
Sharkey, Don
Bates, Declan G.
contents Background: Mechanical ventilation is life-saving for preterm infants with respiratory distress syndrome but can also contribute to lung injury and long-term morbidity. Protective ventilation strategies are recommended, yet implementation in neonatal intensive care units remains inconsistent, and infants continue to be exposed to injurious ventilator settings. Objective: To develop and validate a cohort of neonatal digital twins, based on mechanistic models of cardiopulmonary physiology calibrated to individual patient data, as a tool for simulating and optimising protective ventilation strategies. Methods: A high-fidelity computational simulator of human cardiopulmonary physiology was adapted to neonatal-specific parameters, including lung compliance, dead space, pulmonary vascular resistance, oxygen consumption, and fetal haemoglobin oxygen affinity. Digital twins were generated using data at 65 time points from 11 preterm neonates receiving volume-controlled ventilation. Model parameters were calibrated to minimise the error between simulated and observed PaO2, PaCO2, and peak inspiratory pressure (PIP). Results: Digital twins reproduced measured data with mean absolute percentage errors of 3.9% (PaO2), 3.0% (PaCO2), and 5.8% (PIP) across the cohort. Predictions for uncalibrated variables (pHa, SaO2, mean and minimum airway pressure) also showed high accuracy, with errors <5%. Strong correlations and narrow limits of agreement were observed across all patients and time points. Conclusions: This study demonstrates, for the first time, the feasibility of creating fully mechanistic digital twins of mechanically ventilated neonates with RDS. The twins accurately captured patient-specific gas exchange and respiratory mechanics, supporting their potential as a platform for conducting virtual clinical trials and for the design of individualized, lung-protective ventilation strategies.
format Preprint
id arxiv_https___arxiv_org_abs_2509_18999
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Digital Twins of Mechanically Ventilated Preterm Neonates with Respiratory Distress Syndrome
Saffaran, Sina
Kwok, Tng Chang
Sharkey, Don
Bates, Declan G.
Medical Physics
Background: Mechanical ventilation is life-saving for preterm infants with respiratory distress syndrome but can also contribute to lung injury and long-term morbidity. Protective ventilation strategies are recommended, yet implementation in neonatal intensive care units remains inconsistent, and infants continue to be exposed to injurious ventilator settings. Objective: To develop and validate a cohort of neonatal digital twins, based on mechanistic models of cardiopulmonary physiology calibrated to individual patient data, as a tool for simulating and optimising protective ventilation strategies. Methods: A high-fidelity computational simulator of human cardiopulmonary physiology was adapted to neonatal-specific parameters, including lung compliance, dead space, pulmonary vascular resistance, oxygen consumption, and fetal haemoglobin oxygen affinity. Digital twins were generated using data at 65 time points from 11 preterm neonates receiving volume-controlled ventilation. Model parameters were calibrated to minimise the error between simulated and observed PaO2, PaCO2, and peak inspiratory pressure (PIP). Results: Digital twins reproduced measured data with mean absolute percentage errors of 3.9% (PaO2), 3.0% (PaCO2), and 5.8% (PIP) across the cohort. Predictions for uncalibrated variables (pHa, SaO2, mean and minimum airway pressure) also showed high accuracy, with errors <5%. Strong correlations and narrow limits of agreement were observed across all patients and time points. Conclusions: This study demonstrates, for the first time, the feasibility of creating fully mechanistic digital twins of mechanically ventilated neonates with RDS. The twins accurately captured patient-specific gas exchange and respiratory mechanics, supporting their potential as a platform for conducting virtual clinical trials and for the design of individualized, lung-protective ventilation strategies.
title Digital Twins of Mechanically Ventilated Preterm Neonates with Respiratory Distress Syndrome
topic Medical Physics
url https://arxiv.org/abs/2509.18999