Contour-informed inter-patient deformable registration of Head-and-Neck patients

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Ruan, Xingyue, Li, Xia, Li, Muheng, Bachtiary, Barbara, Lomax, Antony, Chen, Zhiling, Zhang, Ye
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866908558558232576
author Ruan, Xingyue
Li, Xia
Li, Muheng
Bachtiary, Barbara
Lomax, Antony
Chen, Zhiling
Zhang, Ye
author_facet Ruan, Xingyue
Li, Xia
Li, Muheng
Bachtiary, Barbara
Lomax, Antony
Chen, Zhiling
Zhang, Ye
contents Background and Purpose: Voxel-based analysis (VBA) helps to identify dose-sensitive regions by aligning individual dose distributions within a common coordinate system (CCS). Accurate deformable image registration (DIR) is essential for addressing anatomical variability across patients. To improve both global and region-specific alignment, we enhanced our in-house DIR algorithm (CPT-DIR) with contour-informed regularisations. We tested its performance for head-and-neck (HN) CT images. Materials and Methods: We developed and evaluated contour-informed CPT-DIR on 37 HN CTs, including 7 with ground-truth dose for warped dose validation. Bone contours were generated using TotalSegmentator, while other organs at risk (OARs) were manually delineated. Contour-based constraints, such as Dice Similarity, were integrated to enhance registration outcome. The global registration results were evaluated using MAE, SSIM and PSNR. Geometric accuracy and warped dose accuracy were assessed using Dice Similarity Coefficient (DSC) and Dose-Organ Overlap (DOO). Constrained and unconstrained CPT-DIR were compared to B-spline. Results: CPT-DIR achieved superior accuracy with a MAE of 98.9\pm6.3 HU, lower than 179.1\pm17.8 HU for B-spline. Incorporating brainstem contours as regularisation improved the DSC from 0.604\pm0.116 to 0.878\pm0.017 and DOO from 0.430\pm0.117 to 0.753\pm0.043 for brainstem. Across all metrics, the enhanced CPT-DIR outperformed the B-spline, confirming its advantages in geometric accuracy. Conclusions: The integration of contour-informed regularisation in CPT-DIR improved DIR accuracy, particularly in dosimetrically relevant regions. This enhanced spatial alignment enabled more precise dose mapping for VBA and demonstrated strong potential for advancing reliable inter-patient dosimetric studies in HN radiotherapy.
format Preprint
id arxiv_https___arxiv_org_abs_2509_21217
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Contour-informed inter-patient deformable registration of Head-and-Neck patients
Ruan, Xingyue
Li, Xia
Li, Muheng
Bachtiary, Barbara
Lomax, Antony
Chen, Zhiling
Zhang, Ye
Medical Physics
Background and Purpose: Voxel-based analysis (VBA) helps to identify dose-sensitive regions by aligning individual dose distributions within a common coordinate system (CCS). Accurate deformable image registration (DIR) is essential for addressing anatomical variability across patients. To improve both global and region-specific alignment, we enhanced our in-house DIR algorithm (CPT-DIR) with contour-informed regularisations. We tested its performance for head-and-neck (HN) CT images. Materials and Methods: We developed and evaluated contour-informed CPT-DIR on 37 HN CTs, including 7 with ground-truth dose for warped dose validation. Bone contours were generated using TotalSegmentator, while other organs at risk (OARs) were manually delineated. Contour-based constraints, such as Dice Similarity, were integrated to enhance registration outcome. The global registration results were evaluated using MAE, SSIM and PSNR. Geometric accuracy and warped dose accuracy were assessed using Dice Similarity Coefficient (DSC) and Dose-Organ Overlap (DOO). Constrained and unconstrained CPT-DIR were compared to B-spline. Results: CPT-DIR achieved superior accuracy with a MAE of 98.9\pm6.3 HU, lower than 179.1\pm17.8 HU for B-spline. Incorporating brainstem contours as regularisation improved the DSC from 0.604\pm0.116 to 0.878\pm0.017 and DOO from 0.430\pm0.117 to 0.753\pm0.043 for brainstem. Across all metrics, the enhanced CPT-DIR outperformed the B-spline, confirming its advantages in geometric accuracy. Conclusions: The integration of contour-informed regularisation in CPT-DIR improved DIR accuracy, particularly in dosimetrically relevant regions. This enhanced spatial alignment enabled more precise dose mapping for VBA and demonstrated strong potential for advancing reliable inter-patient dosimetric studies in HN radiotherapy.
title Contour-informed inter-patient deformable registration of Head-and-Neck patients
topic Medical Physics
url https://arxiv.org/abs/2509.21217