Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness (RBE) for Mandible Osteoradionecrosis in Head and Neck Cancer Radiotherapy

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Chen, Jingyuan, Liu, Zhong, Yang, Yunze, Muller, Olivia M., Liu, Zhengliang, Liu, Tianming, Zeng, Lei, Foote, Robert L., Ma, Daniel J., Patel, Samir H., Liu, Wei
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916970802184192
author Chen, Jingyuan
Liu, Zhong
Yang, Yunze
Muller, Olivia M.
Liu, Zhengliang
Liu, Tianming
Zeng, Lei
Foote, Robert L.
Ma, Daniel J.
Patel, Samir H.
Liu, Wei
author_facet Chen, Jingyuan
Liu, Zhong
Yang, Yunze
Muller, Olivia M.
Liu, Zhengliang
Liu, Tianming
Zeng, Lei
Foote, Robert L.
Ma, Daniel J.
Patel, Samir H.
Liu, Wei
contents Mandible Osteoradionecrosis (ORN) is one of the most severe adverse events (AEs) for head and neck (H&N) cancer radiotherapy. Previous retrospective investigations on real-world data relied on conventional statistical models that primarily elucidate correlation rather than establishing causal relationships. Through the novel causal machine learning, we aim to obtain empirical relative biological effectiveness (RBE) for ORN in H&N cancer patients treated with pencil-beam-scanning proton therapy (PBSPT). 335 patients treated by PBSPT and 931 patients treated by volumetric-modulated arc therapy (VMAT) were included. We use 1:1 case-matching to minimize the imbalance in clinical factors between PBSPT and VMAT. The bias test of standardized mean differences (SMD) was applied on the case-matched patient cohorts. The causal machine learning method, causal forest (CF), was adopted to investigate the causal effects between dosimetric factors and the incidence of ORN. The dose volume constraints (DVCs) for VMAT and PBSPT were derived based on causal effects. RBE values were further empirically derived based on tolerance curves formed from DVCs. 335 VMAT patients were case-matched to 335 PBSPT patients; however, SMD analysis revealed persistent covariate imbalances within each group, indicating residual confounding influence. Using CF modeling, we identified DVCs of mandible ORN and found that PBSPT had lower critical volumes than those of VMAT, leading to empirical RBE exceeding 1.1 in the moderate dose range (1.61 at 40 Gy[RBE=1.1], 1.30 at 50 Gy, and 1.13 at 60 Gy). This study presents a novel application of causal machine learning to evaluate mandible ORN in radiotherapy. The results indicate that proton RBE may significantly exceed 1.1 in the moderate dose range, underscoring the importance of incorporating the variable RBE into PBSPT treatment planning to mitigate the risk of ORN.
format Preprint
id arxiv_https___arxiv_org_abs_2509_21669
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness (RBE) for Mandible Osteoradionecrosis in Head and Neck Cancer Radiotherapy
Chen, Jingyuan
Liu, Zhong
Yang, Yunze
Muller, Olivia M.
Liu, Zhengliang
Liu, Tianming
Zeng, Lei
Foote, Robert L.
Ma, Daniel J.
Patel, Samir H.
Liu, Wei
Medical Physics
Mandible Osteoradionecrosis (ORN) is one of the most severe adverse events (AEs) for head and neck (H&N) cancer radiotherapy. Previous retrospective investigations on real-world data relied on conventional statistical models that primarily elucidate correlation rather than establishing causal relationships. Through the novel causal machine learning, we aim to obtain empirical relative biological effectiveness (RBE) for ORN in H&N cancer patients treated with pencil-beam-scanning proton therapy (PBSPT). 335 patients treated by PBSPT and 931 patients treated by volumetric-modulated arc therapy (VMAT) were included. We use 1:1 case-matching to minimize the imbalance in clinical factors between PBSPT and VMAT. The bias test of standardized mean differences (SMD) was applied on the case-matched patient cohorts. The causal machine learning method, causal forest (CF), was adopted to investigate the causal effects between dosimetric factors and the incidence of ORN. The dose volume constraints (DVCs) for VMAT and PBSPT were derived based on causal effects. RBE values were further empirically derived based on tolerance curves formed from DVCs. 335 VMAT patients were case-matched to 335 PBSPT patients; however, SMD analysis revealed persistent covariate imbalances within each group, indicating residual confounding influence. Using CF modeling, we identified DVCs of mandible ORN and found that PBSPT had lower critical volumes than those of VMAT, leading to empirical RBE exceeding 1.1 in the moderate dose range (1.61 at 40 Gy[RBE=1.1], 1.30 at 50 Gy, and 1.13 at 60 Gy). This study presents a novel application of causal machine learning to evaluate mandible ORN in radiotherapy. The results indicate that proton RBE may significantly exceed 1.1 in the moderate dose range, underscoring the importance of incorporating the variable RBE into PBSPT treatment planning to mitigate the risk of ORN.
title Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness (RBE) for Mandible Osteoradionecrosis in Head and Neck Cancer Radiotherapy
topic Medical Physics
url https://arxiv.org/abs/2509.21669