Organ dose optimization for a point-of-care forearm X-ray photon-counting CT

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Rodesch, Pierre-Antoine, Viry, Anaïs, Khorsi, Mouad, Becce, Fabio, Damet, Jérôme, Manzano, Lucía Gallego
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866915516659007488
author Rodesch, Pierre-Antoine
Viry, Anaïs
Khorsi, Mouad
Becce, Fabio
Damet, Jérôme
Manzano, Lucía Gallego
author_facet Rodesch, Pierre-Antoine
Viry, Anaïs
Khorsi, Mouad
Becce, Fabio
Damet, Jérôme
Manzano, Lucía Gallego
contents Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has been assessed using the computed tomography dose index (CTDI). However, emerging dosimetric approaches aim to enable patient-specific evaluations by estimating organ absorbed doses, providing a more accurate representation of the biological impact. This study investigates spectral shaping for an extremity photon-counting detector (PCD) CT, through organ absorbed dose estimation and image quality evaluation. Method: Monte Carlo simulations were conducted to evaluate various combinations of source voltage and filtration. Tube voltage ranged from 80 to 140 kV, combined with three distinct filtration material and thicknesses. Simulations included three stages: a standardized phantom for CTDI assessment, an adult forearm phantom for organ dose measurement, and an image quality phantom for evaluation of an advanced image quality metric: the detectability index. Results: In a wrist PCD-CT imaging protocol, operating the source at 80 kV can reduce the radiation dose by up to 50%. This reduction is achieved while maintaining the same detectability index value as the standard 120 kV protocol. However, the optimal filtration depends on the organ targeted for dose reduction, as bone and skin benefit from opposing filtration approaches. While CTDI provides a useful initial estimate, it may lead to suboptimal optimization compared to organ-specific dose evaluation. Conclusions: Patient-specific dosimetry based on organ absorbed dose estimation offers a more accurate framework for optimizing CT protocols through spectral shaping than conventional CTDI-based approaches.
format Preprint
id arxiv_https___arxiv_org_abs_2509_22488
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Organ dose optimization for a point-of-care forearm X-ray photon-counting CT
Rodesch, Pierre-Antoine
Viry, Anaïs
Khorsi, Mouad
Becce, Fabio
Damet, Jérôme
Manzano, Lucía Gallego
Medical Physics
Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has been assessed using the computed tomography dose index (CTDI). However, emerging dosimetric approaches aim to enable patient-specific evaluations by estimating organ absorbed doses, providing a more accurate representation of the biological impact. This study investigates spectral shaping for an extremity photon-counting detector (PCD) CT, through organ absorbed dose estimation and image quality evaluation. Method: Monte Carlo simulations were conducted to evaluate various combinations of source voltage and filtration. Tube voltage ranged from 80 to 140 kV, combined with three distinct filtration material and thicknesses. Simulations included three stages: a standardized phantom for CTDI assessment, an adult forearm phantom for organ dose measurement, and an image quality phantom for evaluation of an advanced image quality metric: the detectability index. Results: In a wrist PCD-CT imaging protocol, operating the source at 80 kV can reduce the radiation dose by up to 50%. This reduction is achieved while maintaining the same detectability index value as the standard 120 kV protocol. However, the optimal filtration depends on the organ targeted for dose reduction, as bone and skin benefit from opposing filtration approaches. While CTDI provides a useful initial estimate, it may lead to suboptimal optimization compared to organ-specific dose evaluation. Conclusions: Patient-specific dosimetry based on organ absorbed dose estimation offers a more accurate framework for optimizing CT protocols through spectral shaping than conventional CTDI-based approaches.
title Organ dose optimization for a point-of-care forearm X-ray photon-counting CT
topic Medical Physics
url https://arxiv.org/abs/2509.22488