Salvato in:
Dettagli Bibliografici
Autori principali: Pazmiño, Jorge Campos, Fortin, Marc-Antoine, Fortier, Véronique, McNabb, Evan, Bider, Renée-Claude, van der Kouwe, André, Levesque, Ives R.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:https://arxiv.org/abs/2509.23136
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916974120927232
author Pazmiño, Jorge Campos
Fortin, Marc-Antoine
Fortier, Véronique
McNabb, Evan
Bider, Renée-Claude
van der Kouwe, André
Levesque, Ives R.
author_facet Pazmiño, Jorge Campos
Fortin, Marc-Antoine
Fortier, Véronique
McNabb, Evan
Bider, Renée-Claude
van der Kouwe, André
Levesque, Ives R.
contents Purpose: To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2*), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence and fat-water separation. Theory and Methods: R1f and R1w were calculated with fat-specific and water-specific MP2RAGE signals. R2* and PDFF maps were obtained from fat-water separation applied to the second RAGE block. Sequence parameters optimization was performed via Cramér-Rao lower bounds theory, and we designed four protocols with different combinations of number of echoes and readout gradient schemes (I: 3 echoes unipolar, II: 6 echoes unipolar, III: 6 echoes bipolar, and IV: 10 echoes bipolar). We tested and validated these protocols with numerical simulations, phantom and in vivo experiments. In phantoms, we compared ME-MP2RAGE measurements with inversion recovery spin-echo (IR-SE) global R1 and 3D Fast Low Angle Shot (3D FLASH) R2* and PDFF. In vivo, we scanned the lower leg and neck of a healthy volunteer. Results: Numerical simulations showed accurate quantification of relaxation rates with mean relative bias < 3% and PDFF with mean bias < 0.003 using protocol ME-MP2RAGE IV (10 echoes bipolar). Phantom experiments showed excellent agreement with IR-SE and 3D FLASH measurements. In vivo, measurements in the lower leg and neck were consistent with literature values. Conclusion: We proposed an accurate method for simultaneous quantification of R1f, R1w, R2*, and PDFF from a single acquisition with the ME-MP2RAGE sequence.
format Preprint
id arxiv_https___arxiv_org_abs_2509_23136
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence
Pazmiño, Jorge Campos
Fortin, Marc-Antoine
Fortier, Véronique
McNabb, Evan
Bider, Renée-Claude
van der Kouwe, André
Levesque, Ives R.
Medical Physics
Purpose: To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2*), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence and fat-water separation. Theory and Methods: R1f and R1w were calculated with fat-specific and water-specific MP2RAGE signals. R2* and PDFF maps were obtained from fat-water separation applied to the second RAGE block. Sequence parameters optimization was performed via Cramér-Rao lower bounds theory, and we designed four protocols with different combinations of number of echoes and readout gradient schemes (I: 3 echoes unipolar, II: 6 echoes unipolar, III: 6 echoes bipolar, and IV: 10 echoes bipolar). We tested and validated these protocols with numerical simulations, phantom and in vivo experiments. In phantoms, we compared ME-MP2RAGE measurements with inversion recovery spin-echo (IR-SE) global R1 and 3D Fast Low Angle Shot (3D FLASH) R2* and PDFF. In vivo, we scanned the lower leg and neck of a healthy volunteer. Results: Numerical simulations showed accurate quantification of relaxation rates with mean relative bias < 3% and PDFF with mean bias < 0.003 using protocol ME-MP2RAGE IV (10 echoes bipolar). Phantom experiments showed excellent agreement with IR-SE and 3D FLASH measurements. In vivo, measurements in the lower leg and neck were consistent with literature values. Conclusion: We proposed an accurate method for simultaneous quantification of R1f, R1w, R2*, and PDFF from a single acquisition with the ME-MP2RAGE sequence.
title Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence
topic Medical Physics
url https://arxiv.org/abs/2509.23136