Laboratory and Synchrotron Validation of $μ$-XRF for Sulfur Mapping in CTMP Paper Samples

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Foroughi, F., Bergman, H., Krapohl, D., Rahman, H., Chapman, D., Menk, R. H., Norlin, B.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912659159384064
author Foroughi, F.
Bergman, H.
Krapohl, D.
Rahman, H.
Chapman, D.
Menk, R. H.
Norlin, B.
author_facet Foroughi, F.
Bergman, H.
Krapohl, D.
Rahman, H.
Chapman, D.
Menk, R. H.
Norlin, B.
contents The transition toward renewable, fiber-based packaging requires an improved understanding of chemical modifications in high-yield pulps such as chemithermomechanical pulp (CTMP). Sulfonation uniformity is essential for the energy-efficient production of high-strength CTMP pulp. However, laboratory methods only measure total sulfur and cannot illustrate its distribution at the fiber level, which can be visualized using $μ$-XRF. In this work, we present a laboratory $μ$-XRF system developed at Mid Sweden University and assess its capability to detect light elements in CTMP paper handsheets. A 32 $\times$ 32 point grid scan (1.6-1.6 mm$^2$ field of view, 50 $μ$m step, 300 s/point) successfully resolved sulfur K$α$ (2.31 keV) and calcium K$α$ (3.69 keV) fluorescence without helium flushing. Comparative measurements at the Elettra synchrotron confirmed consistency of sulfur peak position and spatial distribution, with higher spectral resolution and signal-to-noise ratio. Histogram analysis using Wasserstein distance metrics demonstrated close agreement between datasets despite differing acquisition conditions. These results demonstrate that laboratory XRF can reproducibly detect and map sulfur in CTMP fibers under ambient conditions, providing a practical tool to complement synchrotron studies and supporting the development of energy-efficient, fiber-based packaging materials.
format Preprint
id arxiv_https___arxiv_org_abs_2509_24751
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Laboratory and Synchrotron Validation of $μ$-XRF for Sulfur Mapping in CTMP Paper Samples
Foroughi, F.
Bergman, H.
Krapohl, D.
Rahman, H.
Chapman, D.
Menk, R. H.
Norlin, B.
Instrumentation and Detectors
Applied Physics
The transition toward renewable, fiber-based packaging requires an improved understanding of chemical modifications in high-yield pulps such as chemithermomechanical pulp (CTMP). Sulfonation uniformity is essential for the energy-efficient production of high-strength CTMP pulp. However, laboratory methods only measure total sulfur and cannot illustrate its distribution at the fiber level, which can be visualized using $μ$-XRF. In this work, we present a laboratory $μ$-XRF system developed at Mid Sweden University and assess its capability to detect light elements in CTMP paper handsheets. A 32 $\times$ 32 point grid scan (1.6-1.6 mm$^2$ field of view, 50 $μ$m step, 300 s/point) successfully resolved sulfur K$α$ (2.31 keV) and calcium K$α$ (3.69 keV) fluorescence without helium flushing. Comparative measurements at the Elettra synchrotron confirmed consistency of sulfur peak position and spatial distribution, with higher spectral resolution and signal-to-noise ratio. Histogram analysis using Wasserstein distance metrics demonstrated close agreement between datasets despite differing acquisition conditions. These results demonstrate that laboratory XRF can reproducibly detect and map sulfur in CTMP fibers under ambient conditions, providing a practical tool to complement synchrotron studies and supporting the development of energy-efficient, fiber-based packaging materials.
title Laboratory and Synchrotron Validation of $μ$-XRF for Sulfur Mapping in CTMP Paper Samples
topic Instrumentation and Detectors
Applied Physics
url https://arxiv.org/abs/2509.24751