contents High-sensitivity clutter filtering is a fundamental step in ultrasound microvascular imaging. Singular value decomposition (SVD) and robust principal component analysis (rPCA) are the main clutter filtering strategies. However, both strategies are limited in feature modeling and separation of tissue and blood flow for high-quality microvascular imaging. Recently, deep learning-based clutter filtering has shown potential in more thoroughly separating tissue and blood flow signals. However, the existing supervised filters face the lack of interpretability and the training ground truth. While the interpretability issue can be addressed by algorithm deep unfolding, the training ground truth remains unsolved. This paper proposes an unsupervised unfolded rPCA (U2-rPCA) method that preserves mathematical interpretability and is insusceptible to learning labels. Specifically, U2-rPCA is unfolded from an iteratively reweighted least squares (IRLS) rPCA baseline with intrinsic low-rank and sparse regularization. In addition, a sparse-enhancement unit is plugged into the network to strengthen its capability to capture the sparse micro-flow signals. U2-rPCA is like an adaptive filter that is trained with part of the image sequence and then used for the following frames. Experimental validations on a in-silico dataset and public in-vivo datasets demonstrated the outperformance of U2-rPCA when compared with the SVD filter, the rPCA baseline, and another deep learning-based filter. Particularly, the proposed method improved the contrast-to-noise ratio (CNR) of the power Doppler image by 1.91 dB to 8.48 dB compared to other methods. Furthermore, the effectiveness of the building modules of U2-rPCA was validated through ablation studies.
format Preprint
id arxiv_https___arxiv_org_abs_2510_00660
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Unsupervised Unfolded rPCA (U2-rPCA): Deep Interpretable Clutter Filtering for Ultrasound Microvascular Imaging
Li, Huaying
Ye, Chuling
Liao, Manfei
Qu, Xiaobo
Wang, Liansheng
Chen, Yinran
Computer Vision and Pattern Recognition
High-sensitivity clutter filtering is a fundamental step in ultrasound microvascular imaging. Singular value decomposition (SVD) and robust principal component analysis (rPCA) are the main clutter filtering strategies. However, both strategies are limited in feature modeling and separation of tissue and blood flow for high-quality microvascular imaging. Recently, deep learning-based clutter filtering has shown potential in more thoroughly separating tissue and blood flow signals. However, the existing supervised filters face the lack of interpretability and the training ground truth. While the interpretability issue can be addressed by algorithm deep unfolding, the training ground truth remains unsolved. This paper proposes an unsupervised unfolded rPCA (U2-rPCA) method that preserves mathematical interpretability and is insusceptible to learning labels. Specifically, U2-rPCA is unfolded from an iteratively reweighted least squares (IRLS) rPCA baseline with intrinsic low-rank and sparse regularization. In addition, a sparse-enhancement unit is plugged into the network to strengthen its capability to capture the sparse micro-flow signals. U2-rPCA is like an adaptive filter that is trained with part of the image sequence and then used for the following frames. Experimental validations on a in-silico dataset and public in-vivo datasets demonstrated the outperformance of U2-rPCA when compared with the SVD filter, the rPCA baseline, and another deep learning-based filter. Particularly, the proposed method improved the contrast-to-noise ratio (CNR) of the power Doppler image by 1.91 dB to 8.48 dB compared to other methods. Furthermore, the effectiveness of the building modules of U2-rPCA was validated through ablation studies.
title Unsupervised Unfolded rPCA (U2-rPCA): Deep Interpretable Clutter Filtering for Ultrasound Microvascular Imaging