contents We report the electrical (dark) characterization of lumped-element kinetic inductance detectors (LEKIDs) fabricated from a Titanium/Aluminum bilayer and designed for broadband absorption in the W-band (75-110 GHz). These detectors are prototypes for future QCD axion search experiments within the Canfranc Axion Detection Experiment (CADEx), which demand sub 1e-19 W/Hz^0.5 sensitivities under low optical backgrounds. We combine a Mattis-Bardeen analysis to the temperature dependence of the detector parameters with noise spectroscopy to determine the electrical noise equivalent power (NEP). The minimum measured value for the electrical NEP is 3e-19 W/Hz0.5. Across the measured temperature range, we find that quasiparticle lifetime deviates from the expected BCS recombination law. Our analysis suggests that non-equilibrium relaxation is governed by spatial inhomogeneities in the superconducting gap and phonon diffusion effects. This work sets the road-map to achieve suitable and ultra-sensitive detectors in the W-band for dark matter axion search experiments.
format Preprint
id arxiv_https___arxiv_org_abs_2510_01913
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Dark characterization of Ti/Al LEKIDs for the search of axions in the W-band
Rollano, Victor
Laguna, Alejandro Pascual
Rodriguez, David
Calvo, Martino
Magaz, Maria Teresa
Granados, Daniel
Monfardini, Alessandro
Gomez, Alicia
Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
We report the electrical (dark) characterization of lumped-element kinetic inductance detectors (LEKIDs) fabricated from a Titanium/Aluminum bilayer and designed for broadband absorption in the W-band (75-110 GHz). These detectors are prototypes for future QCD axion search experiments within the Canfranc Axion Detection Experiment (CADEx), which demand sub 1e-19 W/Hz^0.5 sensitivities under low optical backgrounds. We combine a Mattis-Bardeen analysis to the temperature dependence of the detector parameters with noise spectroscopy to determine the electrical noise equivalent power (NEP). The minimum measured value for the electrical NEP is 3e-19 W/Hz0.5. Across the measured temperature range, we find that quasiparticle lifetime deviates from the expected BCS recombination law. Our analysis suggests that non-equilibrium relaxation is governed by spatial inhomogeneities in the superconducting gap and phonon diffusion effects. This work sets the road-map to achieve suitable and ultra-sensitive detectors in the W-band for dark matter axion search experiments.
title Dark characterization of Ti/Al LEKIDs for the search of axions in the W-band
topic Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2510.01913