Generating Findings for Jaw Cysts in Dental Panoramic Radiographs Using a GPT-Based VLM: A Preliminary Study on Building a Two-Stage Self-Correction Loop with Structured Output (SLSO) Framework

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Hosokawa, Nanaka, Takahashi, Ryo, Kitano, Tomoya, Iida, Yukihiro, Muramatsu, Chisako, Hayashi, Tatsuro, Seino, Yuta, Zhou, Xiangrong, Hara, Takeshi, Katsumata, Akitoshi, Fujita, Hiroshi
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913043881918464
author Hosokawa, Nanaka
Takahashi, Ryo
Kitano, Tomoya
Iida, Yukihiro
Muramatsu, Chisako
Hayashi, Tatsuro
Seino, Yuta
Zhou, Xiangrong
Hara, Takeshi
Katsumata, Akitoshi
Fujita, Hiroshi
author_facet Hosokawa, Nanaka
Takahashi, Ryo
Kitano, Tomoya
Iida, Yukihiro
Muramatsu, Chisako
Hayashi, Tatsuro
Seino, Yuta
Zhou, Xiangrong
Hara, Takeshi
Katsumata, Akitoshi
Fujita, Hiroshi
contents Vision-language models (VLMs) such as GPT (Generative Pre-Trained Transformer) have shown potential for medical image interpretation; however, challenges remain in generating reliable radiological findings in clinical practice, as exemplified by dental pathologies. This study proposes a Self-correction Loop with Structured Output (SLSO) framework as an integrated processing methodology to enhance the accuracy and reliability of AI-generated findings for jaw cysts in dental panoramic radiographs. Dental panoramic radiographs with jaw cysts were used to implement a 10-step integrated processing framework incorporating image analysis, structured data generation, tooth number extraction, consistency checking, and iterative regeneration. The framework functioned as an external validation mechanism for GPT outputs. Performance was compared against the conventional Chain-of-Thought (CoT) method across seven evaluation items: transparency, internal structure, borders, root resorption, tooth movement, relationships with other structures, and tooth number. The SLSO framework improved output accuracy for multiple items compared to the CoT method, with the most notable improvements observed in tooth number identification, tooth movement detection, and root resorption assessment. In successful cases, consistently structured outputs were achieved after up to five regenerations. The framework enforced explicit negative finding descriptions and suppressed hallucinations, although accurate identification of extensive lesions spanning multiple teeth remained limited. This investigation established the feasibility of the proposed integrated processing methodology and provided a foundation for future validation studies with larger, more diverse datasets.
format Preprint
id arxiv_https___arxiv_org_abs_2510_02001
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Generating Findings for Jaw Cysts in Dental Panoramic Radiographs Using a GPT-Based VLM: A Preliminary Study on Building a Two-Stage Self-Correction Loop with Structured Output (SLSO) Framework
Hosokawa, Nanaka
Takahashi, Ryo
Kitano, Tomoya
Iida, Yukihiro
Muramatsu, Chisako
Hayashi, Tatsuro
Seino, Yuta
Zhou, Xiangrong
Hara, Takeshi
Katsumata, Akitoshi
Fujita, Hiroshi
Computer Vision and Pattern Recognition
Artificial Intelligence
Vision-language models (VLMs) such as GPT (Generative Pre-Trained Transformer) have shown potential for medical image interpretation; however, challenges remain in generating reliable radiological findings in clinical practice, as exemplified by dental pathologies. This study proposes a Self-correction Loop with Structured Output (SLSO) framework as an integrated processing methodology to enhance the accuracy and reliability of AI-generated findings for jaw cysts in dental panoramic radiographs. Dental panoramic radiographs with jaw cysts were used to implement a 10-step integrated processing framework incorporating image analysis, structured data generation, tooth number extraction, consistency checking, and iterative regeneration. The framework functioned as an external validation mechanism for GPT outputs. Performance was compared against the conventional Chain-of-Thought (CoT) method across seven evaluation items: transparency, internal structure, borders, root resorption, tooth movement, relationships with other structures, and tooth number. The SLSO framework improved output accuracy for multiple items compared to the CoT method, with the most notable improvements observed in tooth number identification, tooth movement detection, and root resorption assessment. In successful cases, consistently structured outputs were achieved after up to five regenerations. The framework enforced explicit negative finding descriptions and suppressed hallucinations, although accurate identification of extensive lesions spanning multiple teeth remained limited. This investigation established the feasibility of the proposed integrated processing methodology and provided a foundation for future validation studies with larger, more diverse datasets.
title Generating Findings for Jaw Cysts in Dental Panoramic Radiographs Using a GPT-Based VLM: A Preliminary Study on Building a Two-Stage Self-Correction Loop with Structured Output (SLSO) Framework
topic Computer Vision and Pattern Recognition
Artificial Intelligence
url https://arxiv.org/abs/2510.02001