Glaucoma Detection and Structured OCT Report Generation via a Fine-tuned Multimodal Large Language Model

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Jalili, Jalil, Gavhane, Yashraj, Walker, Evan, Heinke, Anna, Bowd, Christopher, Belghith, Akram, Fazio, Massimo A., Girkin, Christopher A., De Moraes, C. Gustavo, Liebmann, Jeffrey M., Baxter, Sally L., Weinreb, Robert N., Zangwill, Linda M., Christopher, Mark
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918153260367872
author Jalili, Jalil
Gavhane, Yashraj
Walker, Evan
Heinke, Anna
Bowd, Christopher
Belghith, Akram
Fazio, Massimo A.
Girkin, Christopher A.
De Moraes, C. Gustavo
Liebmann, Jeffrey M.
Baxter, Sally L.
Weinreb, Robert N.
Zangwill, Linda M.
Christopher, Mark
author_facet Jalili, Jalil
Gavhane, Yashraj
Walker, Evan
Heinke, Anna
Bowd, Christopher
Belghith, Akram
Fazio, Massimo A.
Girkin, Christopher A.
De Moraes, C. Gustavo
Liebmann, Jeffrey M.
Baxter, Sally L.
Weinreb, Robert N.
Zangwill, Linda M.
Christopher, Mark
contents Objective: To develop an explainable multimodal large language model (MM-LLM) that (1) screens optic nerve head (ONH) OCT circle scans for quality and (2) generates structured clinical reports that include glaucoma diagnosis and sector-wise retinal nerve fiber layer (RNFL) thinning assessments. Design: Retrospective cohort study of 1,310 subjects contributing 43,849 Spectralis ONH OCT circle scans (1,331 glaucomatous and 867 healthy eyes) from the DIGS and ADAGES cohorts. Methods: A MM-LLM (Llama 3.2 Vision-Instruct model) was fine-tuned to generate clinical descriptions of OCT imaging data. Training data included paired OCT images and automatically generated, structured clinical reports that described global and sectoral RNFL thinning. Poor-quality scans were labeled as unusable and paired with a fixed refusal statement. The model was evaluated on a held-out test set for three tasks: quality assessment, glaucoma detection, and RNFL thinning classification across seven anatomical sectors. Evaluation metrics included accuracy, sensitivity, specificity, precision, and F1-score. Model description quality was also evaluated using standard text evaluation metrics. Results: The model achieved 0.90 accuracy and 0.98 specificity for quality triage. For glaucoma detection, accuracy was 0.86 (sensitivity 0.91, specificity 0.73, F1-score 0.91). RNFL thinning prediction accuracy ranged from 0.83 to 0.94, with highest performance in global and temporal sectors. Text generation scores showed strong alignment with reference reports (BLEU: 0.82; ROUGE-1: 0.94; ROUGE-2: 0.87; ROUGE-L: 0.92; BERTScore-F1: 0.99). Conclusions: The fine-tuned MM-LLM generated accurate clinical descriptions based on OCT imaging. The model achieved high accuracy in identifying image quality issues and detecting glaucoma. The model also provided sectoral descriptions of RNFL thinning to help support clinical OCT evaluation.
format Preprint
id arxiv_https___arxiv_org_abs_2510_02403
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Glaucoma Detection and Structured OCT Report Generation via a Fine-tuned Multimodal Large Language Model
Jalili, Jalil
Gavhane, Yashraj
Walker, Evan
Heinke, Anna
Bowd, Christopher
Belghith, Akram
Fazio, Massimo A.
Girkin, Christopher A.
De Moraes, C. Gustavo
Liebmann, Jeffrey M.
Baxter, Sally L.
Weinreb, Robert N.
Zangwill, Linda M.
Christopher, Mark
Quantitative Methods
Artificial Intelligence
Computer Vision and Pattern Recognition
Objective: To develop an explainable multimodal large language model (MM-LLM) that (1) screens optic nerve head (ONH) OCT circle scans for quality and (2) generates structured clinical reports that include glaucoma diagnosis and sector-wise retinal nerve fiber layer (RNFL) thinning assessments. Design: Retrospective cohort study of 1,310 subjects contributing 43,849 Spectralis ONH OCT circle scans (1,331 glaucomatous and 867 healthy eyes) from the DIGS and ADAGES cohorts. Methods: A MM-LLM (Llama 3.2 Vision-Instruct model) was fine-tuned to generate clinical descriptions of OCT imaging data. Training data included paired OCT images and automatically generated, structured clinical reports that described global and sectoral RNFL thinning. Poor-quality scans were labeled as unusable and paired with a fixed refusal statement. The model was evaluated on a held-out test set for three tasks: quality assessment, glaucoma detection, and RNFL thinning classification across seven anatomical sectors. Evaluation metrics included accuracy, sensitivity, specificity, precision, and F1-score. Model description quality was also evaluated using standard text evaluation metrics. Results: The model achieved 0.90 accuracy and 0.98 specificity for quality triage. For glaucoma detection, accuracy was 0.86 (sensitivity 0.91, specificity 0.73, F1-score 0.91). RNFL thinning prediction accuracy ranged from 0.83 to 0.94, with highest performance in global and temporal sectors. Text generation scores showed strong alignment with reference reports (BLEU: 0.82; ROUGE-1: 0.94; ROUGE-2: 0.87; ROUGE-L: 0.92; BERTScore-F1: 0.99). Conclusions: The fine-tuned MM-LLM generated accurate clinical descriptions based on OCT imaging. The model achieved high accuracy in identifying image quality issues and detecting glaucoma. The model also provided sectoral descriptions of RNFL thinning to help support clinical OCT evaluation.
title Glaucoma Detection and Structured OCT Report Generation via a Fine-tuned Multimodal Large Language Model
topic Quantitative Methods
Artificial Intelligence
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2510.02403