| contents | Data center loads have expanded significantly in recent years. Compared to traditional loads, data centers are highly sensitive to voltage deviations and thus their protection mechanisms trip more proactively during voltage fluctuations. During a grid fault, simultaneous tripping of large-scale data centers can further destabilize the transmission system and even lead to cascading failures. In response, transmission system operators are imposing voltage ride-through (VRT) requirements for data centers. In this work, we enhance the VRT capability of data centers by designing voltage controllers for their internal power distribution network. We first systematically analyze VRT standards and the controllable resources related to data centers. These resources enable the design of voltage control strategies to regulate voltages internal to the data center, thereby allowing loads to remain online during voltage disturbances from the external transmission grid. We study and contrast both centralized and decentralized controllers that unify the control of heterogeneous flexible resources. Additionally, we construct an integrated test system that simulates both the transient fault response of the transmission system and the data center distribution network. Case studies demonstrate that the proposed voltage control mechanisms provide effective yet simple solutions to enhance data center low-voltage ride-through capability. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2510_03867 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Enhancing Data Center Low-Voltage Ride-Through Xie, Yiheng Cui, Wenqi Wierman, Adam Systems and Control Data center loads have expanded significantly in recent years. Compared to traditional loads, data centers are highly sensitive to voltage deviations and thus their protection mechanisms trip more proactively during voltage fluctuations. During a grid fault, simultaneous tripping of large-scale data centers can further destabilize the transmission system and even lead to cascading failures. In response, transmission system operators are imposing voltage ride-through (VRT) requirements for data centers. In this work, we enhance the VRT capability of data centers by designing voltage controllers for their internal power distribution network. We first systematically analyze VRT standards and the controllable resources related to data centers. These resources enable the design of voltage control strategies to regulate voltages internal to the data center, thereby allowing loads to remain online during voltage disturbances from the external transmission grid. We study and contrast both centralized and decentralized controllers that unify the control of heterogeneous flexible resources. Additionally, we construct an integrated test system that simulates both the transient fault response of the transmission system and the data center distribution network. Case studies demonstrate that the proposed voltage control mechanisms provide effective yet simple solutions to enhance data center low-voltage ride-through capability. |
| title | Enhancing Data Center Low-Voltage Ride-Through |
| topic | Systems and Control |
| url | https://arxiv.org/abs/2510.03867 |