Operational early warning of thunderstorm-driven power outages from open data: a two-stage machine learning approach

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Stanishevska, Iryna, Guikema, Seth
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917188190863360
author Stanishevska, Iryna
Guikema, Seth
author_facet Stanishevska, Iryna
Guikema, Seth
contents Thunderstorm-driven power outages are difficult to predict because most storms do not cause damage, convective processes occur rapidly and chaotically, and the available public data are noisy and incomplete. Severe convective storms now account for a large and rising share of U.S. weather losses, yet thunderstorm-induced outages remain understudied. We develop a 48-hour early-warning model for summer thunderstorm-related outages in Michigan using only open-source outage (EAGLE-I) and weather (METAR) data. Relative to prior work, we (i) rely solely on public data, (ii) preserve convective extremes from a sparse station network via parameter-specific kriging and causal spatiotemporal features, and (iii) use a multi-level LSTM-based architecture evaluated on event-centric peak metrics. The pipeline builds rolling and k-NN inverse-distance aggregates to capture moisture advection, wind shifts, and pressure drops. A two-stage design uses a logistic gate followed by a long short-term memory (LSTM) regressor to filter routine periods and limit noise exposure. Evaluation focuses on state-level peaks of at least 50,000 customers without power, using hits, misses, false alarms, and peak-conditional MASE (cMASE) within 48-hour windows, with uncertainty quantified by block bootstrapping. On the test sample, the Two-Stage model detects more peaks with only one additional false alarm and reduces cMASE near peaks, providing event-focused early warnings without the utility-specific data.
format Preprint
id arxiv_https___arxiv_org_abs_2510_03959
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Operational early warning of thunderstorm-driven power outages from open data: a two-stage machine learning approach
Stanishevska, Iryna
Guikema, Seth
Machine Learning
Thunderstorm-driven power outages are difficult to predict because most storms do not cause damage, convective processes occur rapidly and chaotically, and the available public data are noisy and incomplete. Severe convective storms now account for a large and rising share of U.S. weather losses, yet thunderstorm-induced outages remain understudied. We develop a 48-hour early-warning model for summer thunderstorm-related outages in Michigan using only open-source outage (EAGLE-I) and weather (METAR) data. Relative to prior work, we (i) rely solely on public data, (ii) preserve convective extremes from a sparse station network via parameter-specific kriging and causal spatiotemporal features, and (iii) use a multi-level LSTM-based architecture evaluated on event-centric peak metrics. The pipeline builds rolling and k-NN inverse-distance aggregates to capture moisture advection, wind shifts, and pressure drops. A two-stage design uses a logistic gate followed by a long short-term memory (LSTM) regressor to filter routine periods and limit noise exposure. Evaluation focuses on state-level peaks of at least 50,000 customers without power, using hits, misses, false alarms, and peak-conditional MASE (cMASE) within 48-hour windows, with uncertainty quantified by block bootstrapping. On the test sample, the Two-Stage model detects more peaks with only one additional false alarm and reduces cMASE near peaks, providing event-focused early warnings without the utility-specific data.
title Operational early warning of thunderstorm-driven power outages from open data: a two-stage machine learning approach
topic Machine Learning
url https://arxiv.org/abs/2510.03959