Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Singh, Robinjeet, Roy, Avirup, Becker, Daniel, Gard, Johnathan D., Keller, Mark W., Mates, John A. B., Morgan, Kelsey M., Ortiz, Nathan J., Schmidt, Daniel R., Swetz, Daniel S., Ullom, Joel N., Vale, Leila R., Vissers, Michael, O'Neil, Galen C., Weber, Joel C.
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917353826025472
author Singh, Robinjeet
Roy, Avirup
Becker, Daniel
Gard, Johnathan D.
Keller, Mark W.
Mates, John A. B.
Morgan, Kelsey M.
Ortiz, Nathan J.
Schmidt, Daniel R.
Swetz, Daniel S.
Ullom, Joel N.
Vale, Leila R.
Vissers, Michael
O'Neil, Galen C.
Weber, Joel C.
author_facet Singh, Robinjeet
Roy, Avirup
Becker, Daniel
Gard, Johnathan D.
Keller, Mark W.
Mates, John A. B.
Morgan, Kelsey M.
Ortiz, Nathan J.
Schmidt, Daniel R.
Swetz, Daniel S.
Ullom, Joel N.
Vale, Leila R.
Vissers, Michael
O'Neil, Galen C.
Weber, Joel C.
contents Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to many of these arrays is the efficient use of focal plane area to achieve a large fill fraction of absorbers coupled to detectors. We are developing an integrated fabrication of soft X-ray transition edge sensors (TES) and microwave SQUID multiplexers ($μ$MUX) with the goal of maximizing the fill fraction of the focal plane area on a scale of many thousand pixel detectors. We will utilize lithographically defined high density interconnects to circumvent limitations in existing solutions that use wirebonds or flip-chip bonds. Here we report the first demonstration of combining TES and $μ$MUX processes into a single TES-System-on-a-Chip (TES-SoC) fabrication on a silicon wafer. The $μ$MUX SQUIDs and TES electrothermal feedback circuits are microfabricated first and protected with passivating SiO$_2$, then the TES devices and TES-to-SQUID interconnects are fabricated, and finally the protective layer is removed before the fabrication of the microwave resonators. We show that the microwave SQUIDs are functional and have reasonable yield, and that we are able to read out the transition temperature of the connected TESs using those SQUIDs.
format Preprint
id arxiv_https___arxiv_org_abs_2510_07690
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers
Singh, Robinjeet
Roy, Avirup
Becker, Daniel
Gard, Johnathan D.
Keller, Mark W.
Mates, John A. B.
Morgan, Kelsey M.
Ortiz, Nathan J.
Schmidt, Daniel R.
Swetz, Daniel S.
Ullom, Joel N.
Vale, Leila R.
Vissers, Michael
O'Neil, Galen C.
Weber, Joel C.
Instrumentation and Detectors
Superconductivity
Applied Physics
Quantum Physics
Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to many of these arrays is the efficient use of focal plane area to achieve a large fill fraction of absorbers coupled to detectors. We are developing an integrated fabrication of soft X-ray transition edge sensors (TES) and microwave SQUID multiplexers ($μ$MUX) with the goal of maximizing the fill fraction of the focal plane area on a scale of many thousand pixel detectors. We will utilize lithographically defined high density interconnects to circumvent limitations in existing solutions that use wirebonds or flip-chip bonds. Here we report the first demonstration of combining TES and $μ$MUX processes into a single TES-System-on-a-Chip (TES-SoC) fabrication on a silicon wafer. The $μ$MUX SQUIDs and TES electrothermal feedback circuits are microfabricated first and protected with passivating SiO$_2$, then the TES devices and TES-to-SQUID interconnects are fabricated, and finally the protective layer is removed before the fabrication of the microwave resonators. We show that the microwave SQUIDs are functional and have reasonable yield, and that we are able to read out the transition temperature of the connected TESs using those SQUIDs.