Stochastic numerical head phantoms to enable virtual imaging studies of transcranial photoacoustic computed tomography

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Huang, Hsuan-Kai, Kuo, Joseph, Park, Seonyeong, Villa, Umberto, Wang, Lihong V., Anastasio, Mark A.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866914087468793856
author Huang, Hsuan-Kai
Kuo, Joseph
Park, Seonyeong
Villa, Umberto
Wang, Lihong V.
Anastasio, Mark A.
author_facet Huang, Hsuan-Kai
Kuo, Joseph
Park, Seonyeong
Villa, Umberto
Wang, Lihong V.
Anastasio, Mark A.
contents Transcranial photoacoustic computed tomography (PACT) is an emerging neuroimaging modality, but skull-induced aberrations can result in severe image artifacts if not compensated for during image reconstruction. The development of advanced image reconstruction methods for transcranial PACT is hindered by the lack of well-characterized, clinically relevant evaluation frameworks. Virtual imaging studies offer a solution, but require realistic numerical phantoms. To address this need, this study introduces a framework for generating ensembles of realistic 3D numerical head phantoms for virtual imaging studies. The framework uses adjunct CT data to create anatomical phantoms, which are then enhanced with stochastically synthesized vasculature and assigned realistic optical and acoustic-elastic properties. The utility of the framework is demonstrated through a case study on the impact of skull modeling errors on transcranial PACT image quality. By allowing researchers to assess and refine reconstruction methods meaningfully, the presented framework is expected to accelerate the development of transcranial PACT.
format Preprint
id arxiv_https___arxiv_org_abs_2510_09758
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Stochastic numerical head phantoms to enable virtual imaging studies of transcranial photoacoustic computed tomography
Huang, Hsuan-Kai
Kuo, Joseph
Park, Seonyeong
Villa, Umberto
Wang, Lihong V.
Anastasio, Mark A.
Medical Physics
Transcranial photoacoustic computed tomography (PACT) is an emerging neuroimaging modality, but skull-induced aberrations can result in severe image artifacts if not compensated for during image reconstruction. The development of advanced image reconstruction methods for transcranial PACT is hindered by the lack of well-characterized, clinically relevant evaluation frameworks. Virtual imaging studies offer a solution, but require realistic numerical phantoms. To address this need, this study introduces a framework for generating ensembles of realistic 3D numerical head phantoms for virtual imaging studies. The framework uses adjunct CT data to create anatomical phantoms, which are then enhanced with stochastically synthesized vasculature and assigned realistic optical and acoustic-elastic properties. The utility of the framework is demonstrated through a case study on the impact of skull modeling errors on transcranial PACT image quality. By allowing researchers to assess and refine reconstruction methods meaningfully, the presented framework is expected to accelerate the development of transcranial PACT.