ZACH-ViT: A Zero-Token Vision Transformer with ShuffleStrides Data Augmentation for Robust Lung Ultrasound Classification

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Angelakis, Athanasios, Mousa, Amne, Heldeweg, Micah L. A., Biesheuvel, Laurens A., Haaksma, Mark A., Smit, Jasper M., Tuinman, Pieter R., Elbers, Paul W. G.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908603562065920
author Angelakis, Athanasios
Mousa, Amne
Heldeweg, Micah L. A.
Biesheuvel, Laurens A.
Haaksma, Mark A.
Smit, Jasper M.
Tuinman, Pieter R.
Elbers, Paul W. G.
author_facet Angelakis, Athanasios
Mousa, Amne
Heldeweg, Micah L. A.
Biesheuvel, Laurens A.
Haaksma, Mark A.
Smit, Jasper M.
Tuinman, Pieter R.
Elbers, Paul W. G.
contents Differentiating cardiogenic pulmonary oedema (CPE) from non-cardiogenic and structurally normal lungs in lung ultrasound (LUS) videos remains challenging due to the high visual variability of non-cardiogenic inflammatory patterns (NCIP/ARDS-like), interstitial lung disease, and healthy lungs. This heterogeneity complicates automated classification as overlapping B-lines and pleural artefacts are common. We introduce ZACH-ViT (Zero-token Adaptive Compact Hierarchical Vision Transformer), a 0.25 M-parameter Vision Transformer variant that removes both positional embeddings and the [CLS] token, making it fully permutation-invariant and suitable for unordered medical image data. To enhance generalization, we propose ShuffleStrides Data Augmentation (SSDA), which permutes probe-view sequences and frame orders while preserving anatomical validity. ZACH-ViT was evaluated on 380 LUS videos from 95 critically ill patients against nine state-of-the-art baselines. Despite the heterogeneity of the non-cardiogenic group, ZACH-ViT achieved the highest validation and test ROC-AUC (0.80 and 0.79) with balanced sensitivity (0.60) and specificity (0.91), while all competing models collapsed to trivial classification. It trains 1.35x faster than Minimal ViT (0.62M parameters) with 2.5x fewer parameters, supporting real-time clinical deployment. These results show that aligning architectural design with data structure can outperform scale in small-data medical imaging.
format Preprint
id arxiv_https___arxiv_org_abs_2510_17650
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle ZACH-ViT: A Zero-Token Vision Transformer with ShuffleStrides Data Augmentation for Robust Lung Ultrasound Classification
Angelakis, Athanasios
Mousa, Amne
Heldeweg, Micah L. A.
Biesheuvel, Laurens A.
Haaksma, Mark A.
Smit, Jasper M.
Tuinman, Pieter R.
Elbers, Paul W. G.
Machine Learning
Computer Vision and Pattern Recognition
Differentiating cardiogenic pulmonary oedema (CPE) from non-cardiogenic and structurally normal lungs in lung ultrasound (LUS) videos remains challenging due to the high visual variability of non-cardiogenic inflammatory patterns (NCIP/ARDS-like), interstitial lung disease, and healthy lungs. This heterogeneity complicates automated classification as overlapping B-lines and pleural artefacts are common. We introduce ZACH-ViT (Zero-token Adaptive Compact Hierarchical Vision Transformer), a 0.25 M-parameter Vision Transformer variant that removes both positional embeddings and the [CLS] token, making it fully permutation-invariant and suitable for unordered medical image data. To enhance generalization, we propose ShuffleStrides Data Augmentation (SSDA), which permutes probe-view sequences and frame orders while preserving anatomical validity. ZACH-ViT was evaluated on 380 LUS videos from 95 critically ill patients against nine state-of-the-art baselines. Despite the heterogeneity of the non-cardiogenic group, ZACH-ViT achieved the highest validation and test ROC-AUC (0.80 and 0.79) with balanced sensitivity (0.60) and specificity (0.91), while all competing models collapsed to trivial classification. It trains 1.35x faster than Minimal ViT (0.62M parameters) with 2.5x fewer parameters, supporting real-time clinical deployment. These results show that aligning architectural design with data structure can outperform scale in small-data medical imaging.
title ZACH-ViT: A Zero-Token Vision Transformer with ShuffleStrides Data Augmentation for Robust Lung Ultrasound Classification
topic Machine Learning
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2510.17650