The beam test facility at Jefferson Lab for the precise energy measurement of future calorimeter concepts

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Berdnikov, Vladimir V., Somov, Alexander
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914104895078400
author Berdnikov, Vladimir V.
Somov, Alexander
author_facet Berdnikov, Vladimir V.
Somov, Alexander
contents In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of secondary leptons at the Jefferson Lab experimental complex, provided by the Hall D pair spectrometer (PS), is an optimal facility for studies aiming to understand the impact of light collection and signal processing on calorimetry energy resolution under real experimental conditions. The light emission and collection processes depend on radiator component quality and type, while signal processing depends on photosensor type and front-end electronics design. Various calorimeter tower components and detector assemblies for current and future NP experiments were tested within the lepton momentum range of (3-6) GeV/c using PS. The energy resolution of the PS itself is estimated to be better than approximately 0.6%.
format Preprint
id arxiv_https___arxiv_org_abs_2510_17834
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle The beam test facility at Jefferson Lab for the precise energy measurement of future calorimeter concepts
Berdnikov, Vladimir V.
Somov, Alexander
Instrumentation and Detectors
Nuclear Experiment
In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of secondary leptons at the Jefferson Lab experimental complex, provided by the Hall D pair spectrometer (PS), is an optimal facility for studies aiming to understand the impact of light collection and signal processing on calorimetry energy resolution under real experimental conditions. The light emission and collection processes depend on radiator component quality and type, while signal processing depends on photosensor type and front-end electronics design. Various calorimeter tower components and detector assemblies for current and future NP experiments were tested within the lepton momentum range of (3-6) GeV/c using PS. The energy resolution of the PS itself is estimated to be better than approximately 0.6%.
title The beam test facility at Jefferson Lab for the precise energy measurement of future calorimeter concepts
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2510.17834