Measuring multi-site pulse transit time with an AI-enabled mmWave radar

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Zhu, Jiangyifei, Yuan, Kuang, Prabhakara, Akarsh, Li, Yunzhi, Wang, Gongwei, Michaelsen, Kelly, Chan, Justin, Kumar, Swarun
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914117513641984
author Zhu, Jiangyifei
Yuan, Kuang
Prabhakara, Akarsh
Li, Yunzhi
Wang, Gongwei
Michaelsen, Kelly
Chan, Justin
Kumar, Swarun
author_facet Zhu, Jiangyifei
Yuan, Kuang
Prabhakara, Akarsh
Li, Yunzhi
Wang, Gongwei
Michaelsen, Kelly
Chan, Justin
Kumar, Swarun
contents Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present the first AI-enabled mmWave system for contactless multi-site PTT measurement using a single radar. By leveraging radar beamforming and deep learning algorithms our system simultaneously measures PTT and estimates diastolic blood pressure at multiple sites. The system was evaluated across three physiological pathways - heart-to-radial artery, heart-to-carotid artery, and mastoid area-to-radial artery -- achieving correlation coefficients of 0.73-0.89 compared to contact-based reference sensors for measuring PTT. Furthermore, the system demonstrated correlation coefficients of 0.90-0.92 for estimating DBP, and achieved a mean error of -1.00-0.62 mmHg and standard deviation of 4.97-5.70 mmHg, meeting the FDA's AAMI guidelines for non-invasive blood pressure monitors. These results suggest that our proposed system has the potential to provide a non-invasive measure of cardiovascular health across multiple regions of the body.
format Preprint
id arxiv_https___arxiv_org_abs_2510_18141
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Measuring multi-site pulse transit time with an AI-enabled mmWave radar
Zhu, Jiangyifei
Yuan, Kuang
Prabhakara, Akarsh
Li, Yunzhi
Wang, Gongwei
Michaelsen, Kelly
Chan, Justin
Kumar, Swarun
Medical Physics
Emerging Technologies
Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present the first AI-enabled mmWave system for contactless multi-site PTT measurement using a single radar. By leveraging radar beamforming and deep learning algorithms our system simultaneously measures PTT and estimates diastolic blood pressure at multiple sites. The system was evaluated across three physiological pathways - heart-to-radial artery, heart-to-carotid artery, and mastoid area-to-radial artery -- achieving correlation coefficients of 0.73-0.89 compared to contact-based reference sensors for measuring PTT. Furthermore, the system demonstrated correlation coefficients of 0.90-0.92 for estimating DBP, and achieved a mean error of -1.00-0.62 mmHg and standard deviation of 4.97-5.70 mmHg, meeting the FDA's AAMI guidelines for non-invasive blood pressure monitors. These results suggest that our proposed system has the potential to provide a non-invasive measure of cardiovascular health across multiple regions of the body.
title Measuring multi-site pulse transit time with an AI-enabled mmWave radar
topic Medical Physics
Emerging Technologies
url https://arxiv.org/abs/2510.18141