Saved in:
Bibliographic Details
Main Authors: Ming, Ying, Lin, Yue, Zhao, Longfei, Li, Gengwan, Tan, Zuopeng, Li, Bing, Xie, Sheng, Song, Wei, Xu, Qiqi
Format: Preprint
Published: 2025
Subjects:
Online Access:https://arxiv.org/abs/2510.21140
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914111423512576
author Ming, Ying
Lin, Yue
Zhao, Longfei
Li, Gengwan
Tan, Zuopeng
Li, Bing
Xie, Sheng
Song, Wei
Xu, Qiqi
author_facet Ming, Ying
Lin, Yue
Zhao, Longfei
Li, Gengwan
Tan, Zuopeng
Li, Bing
Xie, Sheng
Song, Wei
Xu, Qiqi
contents Computed Tomography Pulmonary Angiography (CTPA) is the reference standard for diagnosing pulmonary vascular diseases such as Pulmonary Embolism (PE) and Chronic Thromboembolic Pulmonary Hypertension (CTEPH). However, its reliance on iodinated contrast agents poses risks including nephrotoxicity and allergic reactions, particularly in high-risk patients. This study proposes a method to generate Digital Contrast CTPA (DCCTPA) from Non-Contrast CT (NCCT) scans using a cascaded synthesizer based on Cycle-Consistent Generative Adversarial Networks (CycleGAN). Totally retrospective 410 paired CTPA and NCCT scans were obtained from three centers. The model was trained and validated internally on 249 paired images. Extra dataset that comprising 161 paired images was as test set for model generalization evaluation and downstream clinical tasks validation. Compared with state-of-the-art (SOTA) methods, the proposed method achieved the best comprehensive performance by evaluating quantitative metrics (For validation, MAE: 156.28, PSNR: 20.71 and SSIM: 0.98; For test, MAE: 165.12, PSNR: 20.27 and SSIM: 0.98) and qualitative visualization, demonstrating valid vessel enhancement, superior image fidelity and structural preservation. The approach was further applied to downstream tasks of pulmonary vessel segmentation and vascular quantification. On the test set, the average Dice, clDice, and clRecall of artery and vein pulmonary segmentation was 0.70, 0.71, 0.73 and 0.70, 0.72, 0.75 respectively, all markedly improved compared with NCCT inputs.\@ Inter-class Correlation Coefficient (ICC) for vessel volume between DCCTPA and CTPA was significantly better than that between NCCT and CTPA (Average ICC : 0.81 vs 0.70), indicating effective vascular enhancement in DCCTPA, especially for small vessels.
format Preprint
id arxiv_https___arxiv_org_abs_2510_21140
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Digital Contrast CT Pulmonary Angiography Synthesis from Non-contrast CT for Pulmonary Vascular Disease
Ming, Ying
Lin, Yue
Zhao, Longfei
Li, Gengwan
Tan, Zuopeng
Li, Bing
Xie, Sheng
Song, Wei
Xu, Qiqi
Computer Vision and Pattern Recognition
Computed Tomography Pulmonary Angiography (CTPA) is the reference standard for diagnosing pulmonary vascular diseases such as Pulmonary Embolism (PE) and Chronic Thromboembolic Pulmonary Hypertension (CTEPH). However, its reliance on iodinated contrast agents poses risks including nephrotoxicity and allergic reactions, particularly in high-risk patients. This study proposes a method to generate Digital Contrast CTPA (DCCTPA) from Non-Contrast CT (NCCT) scans using a cascaded synthesizer based on Cycle-Consistent Generative Adversarial Networks (CycleGAN). Totally retrospective 410 paired CTPA and NCCT scans were obtained from three centers. The model was trained and validated internally on 249 paired images. Extra dataset that comprising 161 paired images was as test set for model generalization evaluation and downstream clinical tasks validation. Compared with state-of-the-art (SOTA) methods, the proposed method achieved the best comprehensive performance by evaluating quantitative metrics (For validation, MAE: 156.28, PSNR: 20.71 and SSIM: 0.98; For test, MAE: 165.12, PSNR: 20.27 and SSIM: 0.98) and qualitative visualization, demonstrating valid vessel enhancement, superior image fidelity and structural preservation. The approach was further applied to downstream tasks of pulmonary vessel segmentation and vascular quantification. On the test set, the average Dice, clDice, and clRecall of artery and vein pulmonary segmentation was 0.70, 0.71, 0.73 and 0.70, 0.72, 0.75 respectively, all markedly improved compared with NCCT inputs.\@ Inter-class Correlation Coefficient (ICC) for vessel volume between DCCTPA and CTPA was significantly better than that between NCCT and CTPA (Average ICC : 0.81 vs 0.70), indicating effective vascular enhancement in DCCTPA, especially for small vessels.
title Digital Contrast CT Pulmonary Angiography Synthesis from Non-contrast CT for Pulmonary Vascular Disease
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2510.21140