Patient-specific AI for generation of 3D dosimetry imaging from two 2D-planar measurements

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Lopez-Montes, Alejandro, Seifert, Robert, Delker, Astrid, Boening, Guido, Wang, Jiahui, Clement, Christoph, Afshar-Oromieh, Ali, Rominger, Axel, Shi, Kuangyu
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917039698870272
author Lopez-Montes, Alejandro
Seifert, Robert
Delker, Astrid
Boening, Guido
Wang, Jiahui
Clement, Christoph
Afshar-Oromieh, Ali
Rominger, Axel
Shi, Kuangyu
author_facet Lopez-Montes, Alejandro
Seifert, Robert
Delker, Astrid
Boening, Guido
Wang, Jiahui
Clement, Christoph
Afshar-Oromieh, Ali
Rominger, Axel
Shi, Kuangyu
contents In this work we explored the use of patient specific reinforced learning to generate 3D activity maps from two 2D planar images (anterior and posterior). The solution of this problem remains unachievable using conventional methodologies and is of particular interest for dosimetry in nuclear medicine where approaches for post-therapy distribution of radiopharmaceuticals such as 177Lu-PSMA are typically done via either expensive and long 3D SPECT acquisitions or fast, yet only 2D, planar scintigraphy. Being able to generate 3D activity maps from planar scintigraphy opens the gate for new dosimetry applications removing the need for SPECT and facilitating multi-time point dosimetry studies. Our solution comprises the generation of a patient specific dataset with possible 3D uptake maps of the radiopharmaceuticals withing the anatomy of the individual followed by an AI approach (we explored both the use of 3DUnet and diffusion models) able to generate 3D activity maps from 2D planar images. We have validated our method both in simulation and real planar acquisitions. We observed enhanced results using patient specific reinforcement learning (~20% reduction on MAE and ~5% increase in SSIM) and better organ delineation and patient anatomy especially when combining diffusion models with patient specific training yielding a SSIM=0.89 compared to the ground truth for simulations and 0.73 when compared to a SPECT acquisition performed half an hour after the planar. We believe that our methodology can set a change of paradigm for nuclear medicine dosimetry allowing for 3D quantification using only planar scintigraphy without the need of expensive and time-consuming SPECT leveraging the pre-therapy information of the patients.
format Preprint
id arxiv_https___arxiv_org_abs_2510_21362
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Patient-specific AI for generation of 3D dosimetry imaging from two 2D-planar measurements
Lopez-Montes, Alejandro
Seifert, Robert
Delker, Astrid
Boening, Guido
Wang, Jiahui
Clement, Christoph
Afshar-Oromieh, Ali
Rominger, Axel
Shi, Kuangyu
Medical Physics
Artificial Intelligence
In this work we explored the use of patient specific reinforced learning to generate 3D activity maps from two 2D planar images (anterior and posterior). The solution of this problem remains unachievable using conventional methodologies and is of particular interest for dosimetry in nuclear medicine where approaches for post-therapy distribution of radiopharmaceuticals such as 177Lu-PSMA are typically done via either expensive and long 3D SPECT acquisitions or fast, yet only 2D, planar scintigraphy. Being able to generate 3D activity maps from planar scintigraphy opens the gate for new dosimetry applications removing the need for SPECT and facilitating multi-time point dosimetry studies. Our solution comprises the generation of a patient specific dataset with possible 3D uptake maps of the radiopharmaceuticals withing the anatomy of the individual followed by an AI approach (we explored both the use of 3DUnet and diffusion models) able to generate 3D activity maps from 2D planar images. We have validated our method both in simulation and real planar acquisitions. We observed enhanced results using patient specific reinforcement learning (~20% reduction on MAE and ~5% increase in SSIM) and better organ delineation and patient anatomy especially when combining diffusion models with patient specific training yielding a SSIM=0.89 compared to the ground truth for simulations and 0.73 when compared to a SPECT acquisition performed half an hour after the planar. We believe that our methodology can set a change of paradigm for nuclear medicine dosimetry allowing for 3D quantification using only planar scintigraphy without the need of expensive and time-consuming SPECT leveraging the pre-therapy information of the patients.
title Patient-specific AI for generation of 3D dosimetry imaging from two 2D-planar measurements
topic Medical Physics
Artificial Intelligence
url https://arxiv.org/abs/2510.21362