Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Caldera, Luca, Cavinato, Lara, Ieva, Francesca
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911231230607360
author Caldera, Luca
Cavinato, Lara
Ieva, Francesca
author_facet Caldera, Luca
Cavinato, Lara
Ieva, Francesca
contents The variability introduced by differences in MRI scanner models, acquisition protocols, and imaging sites hinders consistent analysis and generalizability across multicenter studies. We present a novel image-based harmonization framework for 3D T1-weighted brain MRI, which disentangles anatomical content from scanner- and site-specific variations. The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features while reducing inter-site variability. This loss enables separate evaluation of image luminance, contrast, and structural components. Training and validation were performed on multiple publicly available datasets spanning diverse scanners and sites, with testing on both healthy and clinical populations. Harmonization using multiple style targets, including style-agnostic references, produced consistent and high-quality outputs. Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings while maintaining anatomical fidelity. Following harmonization, structural SSIM reached 0.97, luminance SSIM ranged from 0.98 to 0.99, and Wasserstein distances between mean voxel intensity distributions decreased substantially. Downstream tasks showed substantial improvements: mean absolute error for brain age prediction decreased from 5.36 to 3.30 years, and Alzheimer's disease classification AUC increased from 0.78 to 0.85. Overall, our framework enhances cross-site image consistency, preserves anatomical fidelity, and improves downstream model performance, providing a robust and generalizable solution for large-scale multicenter neuroimaging studies.
format Preprint
id arxiv_https___arxiv_org_abs_2510_22073
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement
Caldera, Luca
Cavinato, Lara
Ieva, Francesca
Computer Vision and Pattern Recognition
The variability introduced by differences in MRI scanner models, acquisition protocols, and imaging sites hinders consistent analysis and generalizability across multicenter studies. We present a novel image-based harmonization framework for 3D T1-weighted brain MRI, which disentangles anatomical content from scanner- and site-specific variations. The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features while reducing inter-site variability. This loss enables separate evaluation of image luminance, contrast, and structural components. Training and validation were performed on multiple publicly available datasets spanning diverse scanners and sites, with testing on both healthy and clinical populations. Harmonization using multiple style targets, including style-agnostic references, produced consistent and high-quality outputs. Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings while maintaining anatomical fidelity. Following harmonization, structural SSIM reached 0.97, luminance SSIM ranged from 0.98 to 0.99, and Wasserstein distances between mean voxel intensity distributions decreased substantially. Downstream tasks showed substantial improvements: mean absolute error for brain age prediction decreased from 5.36 to 3.30 years, and Alzheimer's disease classification AUC increased from 0.78 to 0.85. Overall, our framework enhances cross-site image consistency, preserves anatomical fidelity, and improves downstream model performance, providing a robust and generalizable solution for large-scale multicenter neuroimaging studies.
title Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2510.22073