Clinic-Oriented Feasibility of a Sensor-Fused Wearable for Upper-Limb Function
Fuente:
arXiv
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Preprint |
| Published: |
2025
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1866912671864979456 |
|---|---|
| author | Srichaisak, Thanyanee Ieochai, Arissa Aueawattthanaphisut, Aueaphum |
| author_facet | Srichaisak, Thanyanee Ieochai, Arissa Aueawattthanaphisut, Aueaphum |
| contents | Background: Upper-limb weakness and tremor (4--12 Hz) limit activities of daily living (ADL) and reduce adherence to home rehabilitation. Objective: To assess technical feasibility and clinician-relevant signals of a sensor-fused wearable targeting the triceps brachii and extensor pollicis brevis. Methods: A lightweight node integrates surface EMG (1 kHz), IMU (100--200 Hz), and flex/force sensors with on-device INT8 inference (Tiny 1D-CNN/Transformer) and a safety-bounded assist policy (angle/torque/jerk limits; stall/time-out). Healthy adults (n = 12) performed three ADL-like tasks. Primary outcomes: Tremor Index (TI), range of motion (ROM), repetitions (Reps min$^{-1}$). Secondary: EMG median-frequency slope (fatigue trend), closed-loop latency, session completion, and device-related adverse events. Analyses used subject-level paired medians with BCa 95\% CIs; exact Wilcoxon $p$-values are reported in the Results. Results: Assistance was associated with lower tremor prominence and improved task throughput: TI decreased by $-0.092$ (95\% CI [$-0.102$, $-0.079$]), ROM increased by $+12.65\%$ (95\% CI [$+8.43$, $+13.89$]), and Reps rose by $+2.99$ min$^{-1}$ (95\% CI [$+2.61$, $+3.35$]). Median on-device latency was 8.7 ms at a 100 Hz loop rate; all sessions were completed with no device-related adverse events. Conclusions: Multimodal sensing with low-latency, safety-bounded assistance produced improved movement quality (TI $\downarrow$) and throughput (ROM, Reps $\uparrow$) in a pilot technical-feasibility setting, supporting progression to IRB-approved patient studies. Trial registration: Not applicable (pilot non-clinical). |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2510_22913 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Clinic-Oriented Feasibility of a Sensor-Fused Wearable for Upper-Limb Function Srichaisak, Thanyanee Ieochai, Arissa Aueawattthanaphisut, Aueaphum Signal Processing Human-Computer Interaction Machine Learning Robotics Neurons and Cognition Background: Upper-limb weakness and tremor (4--12 Hz) limit activities of daily living (ADL) and reduce adherence to home rehabilitation. Objective: To assess technical feasibility and clinician-relevant signals of a sensor-fused wearable targeting the triceps brachii and extensor pollicis brevis. Methods: A lightweight node integrates surface EMG (1 kHz), IMU (100--200 Hz), and flex/force sensors with on-device INT8 inference (Tiny 1D-CNN/Transformer) and a safety-bounded assist policy (angle/torque/jerk limits; stall/time-out). Healthy adults (n = 12) performed three ADL-like tasks. Primary outcomes: Tremor Index (TI), range of motion (ROM), repetitions (Reps min$^{-1}$). Secondary: EMG median-frequency slope (fatigue trend), closed-loop latency, session completion, and device-related adverse events. Analyses used subject-level paired medians with BCa 95\% CIs; exact Wilcoxon $p$-values are reported in the Results. Results: Assistance was associated with lower tremor prominence and improved task throughput: TI decreased by $-0.092$ (95\% CI [$-0.102$, $-0.079$]), ROM increased by $+12.65\%$ (95\% CI [$+8.43$, $+13.89$]), and Reps rose by $+2.99$ min$^{-1}$ (95\% CI [$+2.61$, $+3.35$]). Median on-device latency was 8.7 ms at a 100 Hz loop rate; all sessions were completed with no device-related adverse events. Conclusions: Multimodal sensing with low-latency, safety-bounded assistance produced improved movement quality (TI $\downarrow$) and throughput (ROM, Reps $\uparrow$) in a pilot technical-feasibility setting, supporting progression to IRB-approved patient studies. Trial registration: Not applicable (pilot non-clinical). |
| title | Clinic-Oriented Feasibility of a Sensor-Fused Wearable for Upper-Limb Function |
| topic | Signal Processing Human-Computer Interaction Machine Learning Robotics Neurons and Cognition |
| url | https://arxiv.org/abs/2510.22913 |