A filtering scheme for confocal laser endomicroscopy (CLE)-video sequences for self-supervised learning

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Porsche, Nils, Müller-Diesing, Flurin, Banerjee, Sweta, Goncalves, Miguel, Aubreville, Marc
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866915617632681984
author Porsche, Nils
Müller-Diesing, Flurin
Banerjee, Sweta
Goncalves, Miguel
Aubreville, Marc
author_facet Porsche, Nils
Müller-Diesing, Flurin
Banerjee, Sweta
Goncalves, Miguel
Aubreville, Marc
contents Confocal laser endomicroscopy (CLE) is a non-invasive, real-time imaging modality that can be used for in-situ, in-vivo imaging and the microstructural analysis of mucous structures. The diagnosis using CLE is, however, complicated by images being hard to interpret for non-experienced physicians. Utilizing machine learning as an augmentative tool would hence be beneficial, but is complicated by the shortage of histopathology-correlated CLE imaging sequences with respect to the plurality of patterns in this domain, leading to overfitting of machine learning models. To overcome this, self-supervised learning (SSL) can be employed on larger unlabeled datasets. CLE is a video-based modality with high inter-frame correlation, leading to a non-stratified data distribution for SSL training. In this work, we propose a filter functionality on CLE video sequences to reduce the dataset redundancy in SSL training and improve SSL training convergence and training efficiency. We use four state-of-the-art baseline networks and a SSL teacher-student network with a vision transformer small backbone for the evaluation. These networks were evaluated on downstream tasks for a sinonasal tumor dataset and a squamous cell carcinoma of the skin dataset. On both datasets, we found the highest test accuracy on the filtered SSL-pretrained model, with 67.48% and 73.52%, both considerably outperforming their non-SSL baselines. Our results show that SSL is an effective method for CLE pretraining. Further, we show that our proposed CLE video filter can be utilized to improve training efficiency in self-supervised scenarios, resulting in a reduction of 67% in training time.
format Preprint
id arxiv_https___arxiv_org_abs_2511_00098
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A filtering scheme for confocal laser endomicroscopy (CLE)-video sequences for self-supervised learning
Porsche, Nils
Müller-Diesing, Flurin
Banerjee, Sweta
Goncalves, Miguel
Aubreville, Marc
Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
Confocal laser endomicroscopy (CLE) is a non-invasive, real-time imaging modality that can be used for in-situ, in-vivo imaging and the microstructural analysis of mucous structures. The diagnosis using CLE is, however, complicated by images being hard to interpret for non-experienced physicians. Utilizing machine learning as an augmentative tool would hence be beneficial, but is complicated by the shortage of histopathology-correlated CLE imaging sequences with respect to the plurality of patterns in this domain, leading to overfitting of machine learning models. To overcome this, self-supervised learning (SSL) can be employed on larger unlabeled datasets. CLE is a video-based modality with high inter-frame correlation, leading to a non-stratified data distribution for SSL training. In this work, we propose a filter functionality on CLE video sequences to reduce the dataset redundancy in SSL training and improve SSL training convergence and training efficiency. We use four state-of-the-art baseline networks and a SSL teacher-student network with a vision transformer small backbone for the evaluation. These networks were evaluated on downstream tasks for a sinonasal tumor dataset and a squamous cell carcinoma of the skin dataset. On both datasets, we found the highest test accuracy on the filtered SSL-pretrained model, with 67.48% and 73.52%, both considerably outperforming their non-SSL baselines. Our results show that SSL is an effective method for CLE pretraining. Further, we show that our proposed CLE video filter can be utilized to improve training efficiency in self-supervised scenarios, resulting in a reduction of 67% in training time.
title A filtering scheme for confocal laser endomicroscopy (CLE)-video sequences for self-supervised learning
topic Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
url https://arxiv.org/abs/2511.00098