MambaNetLK: Enhancing Colonoscopy Point Cloud Registration with Mamba

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Jiang, Linzhe, Huang, Jiayuan, Bano, Sophia, Clarkson, Matthew J., Mao, Zhehua, Hoque, Mobarak I.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914127783395328
author Jiang, Linzhe
Huang, Jiayuan
Bano, Sophia
Clarkson, Matthew J.
Mao, Zhehua
Hoque, Mobarak I.
author_facet Jiang, Linzhe
Huang, Jiayuan
Bano, Sophia
Clarkson, Matthew J.
Mao, Zhehua
Hoque, Mobarak I.
contents Accurate 3D point cloud registration underpins reliable image-guided colonoscopy, directly affecting lesion localization, margin assessment, and navigation safety. However, biological tissue exhibits repetitive textures and locally homogeneous geometry that cause feature degeneracy, while substantial domain shifts between pre-operative anatomy and intra-operative observations further degrade alignment stability. To address these clinically critical challenges, we introduce a novel 3D registration method tailored for endoscopic navigation and a high-quality, clinically grounded dataset to support rigorous and reproducible benchmarking. We introduce C3VD-Raycasting-10k, a large-scale benchmark dataset with 10,014 geometrically aligned point cloud pairs derived from clinical CT data. We propose MambaNetLK, a novel correspondence-free registration framework, which enhances the PointNetLK architecture by integrating a Mamba State Space Model (SSM) as a cross-modal feature extractor. As a result, the proposed framework efficiently captures long-range dependencies with linear-time complexity. The alignment is achieved iteratively using the Lucas-Kanade algorithm. On the clinical dataset, C3VD-Raycasting-10k, MambaNetLK achieves the best performance compared with the state-of-the-art methods, reducing median rotation error by 56.04% and RMSE translation error by 26.19% over the second-best method. The model also demonstrates strong generalization on ModelNet40 and superior robustness to initial pose perturbations. MambaNetLK provides a robust foundation for 3D registration in surgical navigation. The combination of a globally expressive SSM-based feature extractor and a large-scale clinical dataset enables more accurate and reliable guidance systems in minimally invasive procedures like colonoscopy.
format Preprint
id arxiv_https___arxiv_org_abs_2511_00260
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle MambaNetLK: Enhancing Colonoscopy Point Cloud Registration with Mamba
Jiang, Linzhe
Huang, Jiayuan
Bano, Sophia
Clarkson, Matthew J.
Mao, Zhehua
Hoque, Mobarak I.
Computer Vision and Pattern Recognition
68T07 (Primary) 68T45, 92C55 (Secondary)
Accurate 3D point cloud registration underpins reliable image-guided colonoscopy, directly affecting lesion localization, margin assessment, and navigation safety. However, biological tissue exhibits repetitive textures and locally homogeneous geometry that cause feature degeneracy, while substantial domain shifts between pre-operative anatomy and intra-operative observations further degrade alignment stability. To address these clinically critical challenges, we introduce a novel 3D registration method tailored for endoscopic navigation and a high-quality, clinically grounded dataset to support rigorous and reproducible benchmarking. We introduce C3VD-Raycasting-10k, a large-scale benchmark dataset with 10,014 geometrically aligned point cloud pairs derived from clinical CT data. We propose MambaNetLK, a novel correspondence-free registration framework, which enhances the PointNetLK architecture by integrating a Mamba State Space Model (SSM) as a cross-modal feature extractor. As a result, the proposed framework efficiently captures long-range dependencies with linear-time complexity. The alignment is achieved iteratively using the Lucas-Kanade algorithm. On the clinical dataset, C3VD-Raycasting-10k, MambaNetLK achieves the best performance compared with the state-of-the-art methods, reducing median rotation error by 56.04% and RMSE translation error by 26.19% over the second-best method. The model also demonstrates strong generalization on ModelNet40 and superior robustness to initial pose perturbations. MambaNetLK provides a robust foundation for 3D registration in surgical navigation. The combination of a globally expressive SSM-based feature extractor and a large-scale clinical dataset enables more accurate and reliable guidance systems in minimally invasive procedures like colonoscopy.
title MambaNetLK: Enhancing Colonoscopy Point Cloud Registration with Mamba
topic Computer Vision and Pattern Recognition
68T07 (Primary) 68T45, 92C55 (Secondary)
url https://arxiv.org/abs/2511.00260