Analyzing the Impact of Demand Response on Short-Circuit Current via a Unit Commitment Model

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Wang, Peng, Li, Zhengmao, Badesa, Luis
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917216379731968
author Wang, Peng
Li, Zhengmao
Badesa, Luis
author_facet Wang, Peng
Li, Zhengmao
Badesa, Luis
contents In low-carbon grids, system flexibility can be enhanced through mechanisms such as Demand Response (DR), enabling the efficient utilization of renewable energy. However, as Synchronous Generators (SGs) are being replaced by renewable energy sources characterized by Inverter-Based Resources (IBR), system stability is severely affected. Due to the limited overload capability of IBRs, their Short-Circuit Current (SCC) contribution is much smaller than that of SGs. As a result, protection devices may fail to trip during faults. Consequently, the remaining SGs play a key role in providing sufficient SCC. Since the commitment of SGs is closely related to system loading conditions, DR can indirectly affect their SCC provision, a relationship that has not yet been investigated in the literature. Therefore, this paper incorporates both DR and SCC constraints into a unit commitment problem and conducts case studies on an IEEE 30-bus system. The results show that although DR can reduce total costs by adjusting power demand, it may also lead to inadequate SCC levels. Nevertheless, when flexible loads are properly coordinated with SCC requirements, the total cost increases by only 0.3%, which is significantly lower than the cost of system dispatch without DR. This demonstrates that DR can facilitate stable system operation in a cost-effective manner.
format Preprint
id arxiv_https___arxiv_org_abs_2511_00296
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Analyzing the Impact of Demand Response on Short-Circuit Current via a Unit Commitment Model
Wang, Peng
Li, Zhengmao
Badesa, Luis
Systems and Control
In low-carbon grids, system flexibility can be enhanced through mechanisms such as Demand Response (DR), enabling the efficient utilization of renewable energy. However, as Synchronous Generators (SGs) are being replaced by renewable energy sources characterized by Inverter-Based Resources (IBR), system stability is severely affected. Due to the limited overload capability of IBRs, their Short-Circuit Current (SCC) contribution is much smaller than that of SGs. As a result, protection devices may fail to trip during faults. Consequently, the remaining SGs play a key role in providing sufficient SCC. Since the commitment of SGs is closely related to system loading conditions, DR can indirectly affect their SCC provision, a relationship that has not yet been investigated in the literature. Therefore, this paper incorporates both DR and SCC constraints into a unit commitment problem and conducts case studies on an IEEE 30-bus system. The results show that although DR can reduce total costs by adjusting power demand, it may also lead to inadequate SCC levels. Nevertheless, when flexible loads are properly coordinated with SCC requirements, the total cost increases by only 0.3%, which is significantly lower than the cost of system dispatch without DR. This demonstrates that DR can facilitate stable system operation in a cost-effective manner.
title Analyzing the Impact of Demand Response on Short-Circuit Current via a Unit Commitment Model
topic Systems and Control
url https://arxiv.org/abs/2511.00296