Electromagnetic deflection effects in the integrated luminosity measurement at the CEPC

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Smiljanić, Ivan, Božović, Ivanka, Vidaković, Ivana, Vukašinović, Nataša, Kačarević, Goran
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913169087135744
author Smiljanić, Ivan
Božović, Ivanka
Vidaković, Ivana
Vukašinović, Nataša
Kačarević, Goran
author_facet Smiljanić, Ivan
Božović, Ivanka
Vidaković, Ivana
Vukašinović, Nataša
Kačarević, Goran
contents In order to ensure measurement of the integrated luminosity with a relative precision of $\mathrm{10^{-4}}$ at the $\mathrm{Z^{0}}$ pole at CEPC, numerous systematic effects have to be quantified and, if possible, corrected for. Here we discuss the impact of electromagnetic fields of incoming bunches on the initial state electrons and positrons (EMD1) as well as on the Bhabha scattering final states (EMD2). Both effects change four-momenta of the final state particles, leading to a modification of the Bhabha count in the luminometer. These effects are quantified in simulation, together with their stability with respect to the beam parameters variations. Possible correction methods based on experimental measurements with the CEPC detector are discussed on a conceptual level.
format Preprint
id arxiv_https___arxiv_org_abs_2511_00687
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Electromagnetic deflection effects in the integrated luminosity measurement at the CEPC
Smiljanić, Ivan
Božović, Ivanka
Vidaković, Ivana
Vukašinović, Nataša
Kačarević, Goran
High Energy Physics - Experiment
In order to ensure measurement of the integrated luminosity with a relative precision of $\mathrm{10^{-4}}$ at the $\mathrm{Z^{0}}$ pole at CEPC, numerous systematic effects have to be quantified and, if possible, corrected for. Here we discuss the impact of electromagnetic fields of incoming bunches on the initial state electrons and positrons (EMD1) as well as on the Bhabha scattering final states (EMD2). Both effects change four-momenta of the final state particles, leading to a modification of the Bhabha count in the luminometer. These effects are quantified in simulation, together with their stability with respect to the beam parameters variations. Possible correction methods based on experimental measurements with the CEPC detector are discussed on a conceptual level.
title Electromagnetic deflection effects in the integrated luminosity measurement at the CEPC
topic High Energy Physics - Experiment
url https://arxiv.org/abs/2511.00687