Yield and performance validation of the Monolithic Stitched Sensor (MOSS), the first wafer-scale prototype for the ALICE ITS3 upgrade

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autore principale: Menzel, Marius Wilm
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911248545742848
author Menzel, Marius Wilm
author_facet Menzel, Marius Wilm
contents The ALICE Inner Tracking System upgrade (ITS3) will employ stitched, wafer-scale Monolithic Active Pixel Sensors (MAPS) for the first time in high-energy physics, achieving a material budget of only 0.09$\,$%$\,$X$\mathrm{_{0}}$ per layer. Its first stitched prototype, the Monolithic Stitched Sensor (MOSS), underwent serial testing confirming sensor yield compliance with ITS3 requirements. In-beam tests show the device meets the ITS3 efficiency requirement of >$\,$99$\,$% while maintaining a fake-hit rate below 0.1$\,$hits/pixel/s, with performance sustained up to irradiation levels of 4$\,$kGy and $4\times10^{12}$1MeV$\,$n$\mathrm{_{eq}}\,$cm$\mathrm{^{-2}}$. The sensor demonstrates excellent charge-collection properties and linearity between time-over-threshold and deposited energy in the 1.8 - 6.5$\,$keV range in response to soft X-ray emissions. This article provides an overview of the validation steps and characterisation results.
format Preprint
id arxiv_https___arxiv_org_abs_2511_02403
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Yield and performance validation of the Monolithic Stitched Sensor (MOSS), the first wafer-scale prototype for the ALICE ITS3 upgrade
Menzel, Marius Wilm
Instrumentation and Detectors
The ALICE Inner Tracking System upgrade (ITS3) will employ stitched, wafer-scale Monolithic Active Pixel Sensors (MAPS) for the first time in high-energy physics, achieving a material budget of only 0.09$\,$%$\,$X$\mathrm{_{0}}$ per layer. Its first stitched prototype, the Monolithic Stitched Sensor (MOSS), underwent serial testing confirming sensor yield compliance with ITS3 requirements. In-beam tests show the device meets the ITS3 efficiency requirement of >$\,$99$\,$% while maintaining a fake-hit rate below 0.1$\,$hits/pixel/s, with performance sustained up to irradiation levels of 4$\,$kGy and $4\times10^{12}$1MeV$\,$n$\mathrm{_{eq}}\,$cm$\mathrm{^{-2}}$. The sensor demonstrates excellent charge-collection properties and linearity between time-over-threshold and deposited energy in the 1.8 - 6.5$\,$keV range in response to soft X-ray emissions. This article provides an overview of the validation steps and characterisation results.
title Yield and performance validation of the Monolithic Stitched Sensor (MOSS), the first wafer-scale prototype for the ALICE ITS3 upgrade
topic Instrumentation and Detectors
url https://arxiv.org/abs/2511.02403