Improving the Energy and Angular Resolutions of X-ray Telescopes with Nitrogen-Vacancy Centers in Diamond

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Gau, Ephraim, Liu, Zhongyuan, Krawczynski, Henric, Zu, Chong
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911248981950464
author Gau, Ephraim
Liu, Zhongyuan
Krawczynski, Henric
Zu, Chong
author_facet Gau, Ephraim
Liu, Zhongyuan
Krawczynski, Henric
Zu, Chong
contents We introduce a focal-plane detector for advancing the energy and angular resolutions of current X-ray telescopes. The architecture integrates a metallic magnetic microcalorimeter (MMC) array of paramagnetic absorber pads with a thin layer of nitrogen-vacancy (NV) centers in diamond for simultaneous optical readout. An impinging X-ray photon induces a temperature transient in an absorber pad, kept at ~35 mK. This time- and temperature-dependent magnetic field transient is then optically imaged by diamond NV centers, kept at 4 K and positioned directly below the pad. For a 10 $μ$m absorber length used with a 12 m focal length telescope, our design yields an optimal angular resolution of ~0.17 arcseconds and energy resolution of ~0.70 eV. Our NV-MMC design improves upon current transition-edge sensors (TES) or MMCs read-out by superconducting quantum interference devices (SQUID) by enabling simultaneous optical readout of the entire MMC array. Because no additional cryogenic multiplexing electronics are required, our approach scales naturally to larger and finer arrays, supporting finer angular resolutions and wider fields of view.
format Preprint
id arxiv_https___arxiv_org_abs_2511_02961
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Improving the Energy and Angular Resolutions of X-ray Telescopes with Nitrogen-Vacancy Centers in Diamond
Gau, Ephraim
Liu, Zhongyuan
Krawczynski, Henric
Zu, Chong
Instrumentation and Methods for Astrophysics
Quantum Physics
We introduce a focal-plane detector for advancing the energy and angular resolutions of current X-ray telescopes. The architecture integrates a metallic magnetic microcalorimeter (MMC) array of paramagnetic absorber pads with a thin layer of nitrogen-vacancy (NV) centers in diamond for simultaneous optical readout. An impinging X-ray photon induces a temperature transient in an absorber pad, kept at ~35 mK. This time- and temperature-dependent magnetic field transient is then optically imaged by diamond NV centers, kept at 4 K and positioned directly below the pad. For a 10 $μ$m absorber length used with a 12 m focal length telescope, our design yields an optimal angular resolution of ~0.17 arcseconds and energy resolution of ~0.70 eV. Our NV-MMC design improves upon current transition-edge sensors (TES) or MMCs read-out by superconducting quantum interference devices (SQUID) by enabling simultaneous optical readout of the entire MMC array. Because no additional cryogenic multiplexing electronics are required, our approach scales naturally to larger and finer arrays, supporting finer angular resolutions and wider fields of view.
title Improving the Energy and Angular Resolutions of X-ray Telescopes with Nitrogen-Vacancy Centers in Diamond
topic Instrumentation and Methods for Astrophysics
Quantum Physics
url https://arxiv.org/abs/2511.02961