α/γ discrimination method for bulky BaF2 detector used in γ total absorption facility

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Zou, Chong, Zhang, Qiwei, Luan, Guangyuan, Wu, Hongyi, Luo, Haotian, Chen, Xuanbo, Wang, Xiaoyu, He, Guozhu, Ren, Jie, Huang, Hanxiong, Ruan, Xichao, Bao, Jie, Zhu, Xinghua
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909887481511936
author Zou, Chong
Zhang, Qiwei
Luan, Guangyuan
Wu, Hongyi
Luo, Haotian
Chen, Xuanbo
Wang, Xiaoyu
He, Guozhu
Ren, Jie
Huang, Hanxiong
Ruan, Xichao
Bao, Jie
Zhu, Xinghua
author_facet Zou, Chong
Zhang, Qiwei
Luan, Guangyuan
Wu, Hongyi
Luo, Haotian
Chen, Xuanbo
Wang, Xiaoyu
He, Guozhu
Ren, Jie
Huang, Hanxiong
Ruan, Xichao
Bao, Jie
Zhu, Xinghua
contents The gamma-ray total absorption facility (GTAF) composed of 40 BaF2 detection units is designed to measure the cross section data of neutron radiation capture reaction online, in order to comply with the experimental nuclear data sheet.We have found that one of the most important sources of experimental background is the initial alpha particles emitted by the BaF2 crystal. Developing data analysis algorithms to eliminate the influence of alpha particles in experimental data has become a key aspect. In this work, in order to meet the needs of data acquisition, online measurement and analysis of neutron radiation cross section, the GTAF data acquisition system adopts a full waveform acquisition method, which results in a large number of data recorded, transmitted, and stored during experiment, which also affects the uncertainty of the cross-section data.Based on the signal waveform characteristics of the BaF2 detection unit, in order to solve the aforementioned problems, three methods, namely the ratio of fast component to total component, pulse width, and time decay constant, are used to identify and distinguish alpha particles and gamma rays. The quality factor FOM is utilized as an evaluation value and several experiments are conducted using three radioactive sources (22Na, 137Cs, 60Co) for verification.
format Preprint
id arxiv_https___arxiv_org_abs_2511_03139
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle α/γ discrimination method for bulky BaF2 detector used in γ total absorption facility
Zou, Chong
Zhang, Qiwei
Luan, Guangyuan
Wu, Hongyi
Luo, Haotian
Chen, Xuanbo
Wang, Xiaoyu
He, Guozhu
Ren, Jie
Huang, Hanxiong
Ruan, Xichao
Bao, Jie
Zhu, Xinghua
Instrumentation and Detectors
Nuclear Experiment
The gamma-ray total absorption facility (GTAF) composed of 40 BaF2 detection units is designed to measure the cross section data of neutron radiation capture reaction online, in order to comply with the experimental nuclear data sheet.We have found that one of the most important sources of experimental background is the initial alpha particles emitted by the BaF2 crystal. Developing data analysis algorithms to eliminate the influence of alpha particles in experimental data has become a key aspect. In this work, in order to meet the needs of data acquisition, online measurement and analysis of neutron radiation cross section, the GTAF data acquisition system adopts a full waveform acquisition method, which results in a large number of data recorded, transmitted, and stored during experiment, which also affects the uncertainty of the cross-section data.Based on the signal waveform characteristics of the BaF2 detection unit, in order to solve the aforementioned problems, three methods, namely the ratio of fast component to total component, pulse width, and time decay constant, are used to identify and distinguish alpha particles and gamma rays. The quality factor FOM is utilized as an evaluation value and several experiments are conducted using three radioactive sources (22Na, 137Cs, 60Co) for verification.
title α/γ discrimination method for bulky BaF2 detector used in γ total absorption facility
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2511.03139